CompuSTAR CM4000 Automobile Alarm User Manual


 
Option Programming Tables
Option Programming with Remotes and OP500, RPS Unlock and Secure Valet are programmable ONLY when system is Unlocked/Disarmed.
OPTION GROUP 1
Feature Default Setting - I Optional Setting - II Optional Setting - III Optional Setting - IV
1-01 Unlock before, Lock after, starting Off On
Lock After Remote Start
Only
Lock After Shutdown
Only
1-02 Lock / Unlock pulse duration 0.8 sec 2.5 sec 0.125 sec 3.5 sec
1-03 Driver's priority unlock Off On
1-04 Double pulse unlock Off On
1-05 Rearm Output
After Start Shutdown
and First Lock
After Start Shutdown
and Every Lock
After Start Only After Shutdown Only
1-06
Reservation Lock
(Manual transmissions)
Locks When
Reservation Mode is Set
Does Not Lock When
Reservation is Set
Reservation Sets 10
Seconds After the Last
Door is Closed
1-07 Unlock / Disarm With Trunk Release
Unlock, Factory Disarm,
and Trunk Release
Factory Disarm, Trunk
Release Only
Trunk Release Only
1-08 Locking while in Passive Arming
Passive locking with
Passive Arming
No Passive Locking with
Passive Arming
1-09 Ignition controlled door locks Off On
RPM Locks (Tach
Sensing Mode Only)
1-10
Auto Relock (If a door is not opened
within this amount of time)
Off 30 sec 60 sec 5 min
1-11 Ignition / Accessory Out Upon Unlock Off
Ignition Pulse - same
timing as disarm pulse
Acc Pulse - same timing
as disarm pulse
Ignition and Acc Pulse -
same timing as disarm
pulse
1-13 Double Pulse Disarm Input Single Pulse Double Pulse
1-14
Auto Lock Mode (2 Way International
Remotes)
Off On
OPTION GROUP 2
Feature Default Setting - I Optional Setting - II Optional Setting - III Optional Setting - IV
2-01 Tach Sensing Method Optimal Tach Method Previous Tach Method
Low Threshold Tach
Method
2-02 Turbo Timer Off 2 Min 1Min 4 Min
2-03 Diesel Timer Wire 3~99sec (10sec Default)
2-04 Trigger Start Off Single Pulse Double Pulse Triple Pulse
2-05 Cold Start with Thermistor Assembly Off On
2-06
Timer Start, or, Minimum Interval
Between Cold Starts
3 Hour (4 minute
runtime, double for
Diesel)
1.5 Hour(4 minute
runtime, double for
Diesel)
Reservation
(Runtime set by 2-7)
2 Way LCD Remotes
Only
24 Hour Repeat with
Cold Starting of 2-8
(Runtime set by 2-7) 2
Way LCD Only
2-07 Remote Start Runtime 15 Min 25 Min 45 Min 3 Min
2-08 Temperature of Cold Starting -10° C / 14° F -20° C / -4° F -5° C / 23° F -15° C / 5° F
2-09 Temperature of Hot Starting 25° C / 77° F 30° C / 86° F 35° C / 95° F 40° C / 104° F
2-10 Engine Sensing Tach Alternator
No Connection – No
Tach Sensing
(Not for Manual
Transmissions)
No Connection – 1.5
Second Crank
(Not for Manual
Transmissions. V.33 or
greater)
2-11
Turbo, Remote Start Runtime
Extension w/ #1 for 2 seconds
No Yes
2-12 Crank Time Standard
+0.2 Seconds to Crank
Time
+0.6 Seconds to Crank
Time
(No Tach Sensing Only)
(-)0.2 Second Crank
Time
OPTION GROUP 3
Feature Default Setting - I Optional Setting - II Optional Setting - III Optional Setting - IV
3-01 Parking lights While Remote Started Constant Output Flashing Output Off
3-02 Dome Light output Off Factory Rearm 45 sec Factory Rearm + 45 Sec
3-03 Dome Light Delay Off 5 sec 45 sec Auto
3-04 Starter-Kill Relay Anti-Grind + Starter Kill Anti-Grind
Anti-Grind +
Passive Starter Kill
3-05 Anti-Jacking Starter-kill
Ignition-Kill
(no Anti-Grind)
Auto kill
(Auto-door locks Off)
International Remotes
w/ AUTO Function Only
Auto kill
(Auto-door locks On)
International Remotes
w/ AUTO Function Only
3-07 Siren Duration (Upon Alarm Trigger) 30 sec 60 sec 120 Sec Chirps for 20 seconds
3-09 Horn Output When Alarm Is Triggered
Pulsed Output
(Horn)
Constant Output
(Secondary Siren)
3-10 Valet
Key 5 times, or Remote
(I+III) while Ignition is On
Key 5 times or Remote
(I+III)
Secure Valet
(Default code 3,3)
3-11 Auxiliary settings Mode Disabled Enabled
3-12 Auxiliary settings With Passive Arming No Passive Arming Passive Arming