To Exit the SIS-5P adjustment mode, press the “M” & “Lock/Unlock”
buttons together. The siren or horn will sound 4 chirps confirming exit.
The sensor adjust mode will automatically exit in 30 seconds if no signal is
received.
REMOTE TRANSMITTER PROGRAMMING
Programming Transmitter
The RF-505 can program up to 4 transmitters in memory. To enter
programming, follow these steps:
1. Turn the Ignition to the ON position.
2. Within 15 seconds push the valet switch 3 times the siren and/or horn
will sound 1 long chirp.
3. Press the “Lock/Unlock” button on the transmitter #1; there will be 1
short chirp. Repeat for transmitter #2, there will be 2 short chirps.
NOTE: If you are programming transmitters #3 & #4, repeat step 3
for both transmitters.
4. Turn the ignition OFF, there will be 3 long chirps to confirm exit of
transmitter programming mode.
Transmitter Button Actions System Function
+
Press & Hold 5 sec. SIS - 5P Sensor Adjustment Mode
Press 1 Time Increase Sensor Sensitivity
Press 1 Time Decrease Sensor Sensitivity
+ Press 1 Time Exit Sensor Adjustment Mode