3 Wire Positive Switched Door Locks:
In this application, the Red wire of the two pin harness providesa+12volt pulse during the disarming
sequence, or pulsed 12 volt unlock output. Connect the Red wire to the low current 12 volt signal wire from
the factory door unlock switch to the factory door unlock relay.
The Green wire of the two pin harness providesa+12volt pulse during the arming sequence, or pulsed 12
volt lock output. Connect the Green wire to the low current 12 volt signal wire from the factory door lock
switch to the factory door lock relay. See Below For Wiring Detail.
3 Wire Positive Switched Door Lock/Unlock Wiring Detail
Note: For connection to Four Wire Polarity Reversal, 5 Wire Alternating 12 Volts, And All Other Door Lock
Circuits the Audiovox AS-9159 Door Lock Interface, (or equivalent 30 A automotive relays) must be
used. Refer to the Audiovox Door Lock Wiring Supplement for proper wiring of these circuits.
4 Wire Polarity Reversal and
5 Wire Alternating 12 Volt
DoorLock ControlCircuits
Inthese applications,the AS9159 DoorLock Interface( orequivalent30 Aautomotive relays)must beused.
Refer to the AUDIOVOX Door Lock Wiring Supplement for proper connection to these types of circuits.
2 Pin Blue Connector : Programming Switch
Routethe greyandblack wiresinthe 2pinconnector fromthepreviously installedprogrammingswitch tothe
control module and plug it into the mating blue connector on the side of the module.
WIRING THE 4 PIN AUXILIARY OUTPUT HARNESS
The auxiliary 4 pin connector provides low current outputs to control various functions in the vehicle during
different stages of the Remote Start unit's operation. Understanding these outputs and the time in which
they occur will allow you to determine if they are needed for the particular vehicle you are working on as well
as how to use them.
Black w Blue Trace Wire: Pulsed Ground Output Before Start
The Black w/ Blue Trace wire will provide a 1 second 300 mA pulsed ground output 1.5 second before the
remote start unit activates as well as when the transmitter is used to disarm the system. Typical use for this
output would be to disarm a factory theft deterrent system to prevent false triggering of the factory alarm
when the remote start unit engages or when the 9175 is used to unlock the doors.
Black w/ Light Green Trace Wire: Pulsed Ground Output After Start
The Black w/ Light Green Trace wire will provide a 1 second 300mA pulsed ground output after the vehicle is
started under control of the remote start unit. Typically this wire will be used to re-lock the vehicle doors if the
doors unlock automatically when the factory anti-theft system is disarmed.
Black w/ Red Trace Wire: Pulsed Ground Output After Shutdown
The Black w/ Red Trace wire will provid e a 1 second 300 mA pulsed ground output after the remote start unit
shuts down. This output will occur regardless of whether the circuit times out or is manually terminated.
9