steps 1 through 7 above considering the following.
NOTE: Acceptable digits 10ths or units are 1 through 9. The unit will not
recognize a 0 (Zero), or no digit entered in any place, units or tenths.
NOTE: If 15 seconds of inactivity expire or if the ignition switch is turned off for
more then 5 seconds during any of the above steps, the unit will revert
back to the last successfully stored code.
Custom Code Programming Example:
To Change the code from the factory preassigned code of 11 to “52” you would do
the following:
1. Disarm the system by use of the transmitter or by use of the emergency
override sequence.
2. Turn the ignition switch to the on position.
3. Within 10 seconds, press and release the valet/override switch, 3 times.
4. Within 10 seconds turn the ignition switch off, on, off, on, off, on.
(The siren or horn will beep and the lights will flash one time.)
5. Within 10 seconds, begin to press and release the pushbutton switch to set
the tenths digit.
(As per the example, press and release 5 times to set the tenths digit to 5)
6. Within 10 seconds of the last press of the pushbutton, turn the ignition switch
off then on.
7. Within 10 seconds, begin to press and release the pushbutton switch to set
the units digit.
(As per the example, press and release 2 times to set the units digit to 2).
8. Turn the ignition switch to the off position. Immediately observe the LED flash
pattern.
You will note the LED flashing five times, pause, and then flash two times, pause.
This pattern will be repeated three times indicating the new code (52) has been
accepted and stored in memory.
NOTE: If after step 7, the LED flashes a code other than what was just entered,
this indicates that the code has not been changed. You will have to repeat
steps 1 through 7 above being certain to note the following:
Acceptable digits 10ths or units are 1 through 9. The unit will not recognize a 0
(Zero), or no digit entered in any place, units or tenths.
NOTE: If 15 seconds of inactivity expire, or if the ignition switch is turned off for
more then 5 seconds during any of the above steps, the unit will revert
back to the last successfully stored code.
MANUALLY OVERRIDING YOUR SYSTEM:
USING THE CUSTOM CODE OVERRIDE
Assuming the override code programmed has not been changed, and the default
override code of 11 is in the system's memory.
1. Enter the vehicle and turn the ignition switch to the on position.
NOTE: The siren will sound.
2. Within 5 seconds, press and release the pushbutton switch 1 time.
3. Within 5 seconds, turn the ignition switch off then on.
4. Within 5 seconds, press and release the pushbutton switch 1 time.
Page 8