Allstar Products Group MH5011S Automobile Parts User Manual


 
TO REDUCE THE RISK OF SEVERE INJURY
OR DEATH: READ AND FOLLOW ALL
INSTALLATION INSTRUCTIONS!
WARNING
Install only on a properly balanced garage
door. An improperly balanced door could
cause severe injury. Have a qualified service
person make repairs to cables, spring
assemblies and other hardware before
installing the opener.
Remove all ropes and remove or make
inoperative all locks (unless mechanically
and/or electrically interlocked to the power
unit) that are connected to the garage door
before installing the opener.
Lightweight doors (fiberglass, aluminum
etc.) must be reinforced to avoid door
damage. Check the door manufacturer’s
instruction manual for a bracing procedure
or the availability or a Reinforcement Kit.
Allstar Model MJ5011S and MH5011S are
Commercial Vehicular Door Operators and
as such are NOT recommended for
pedestrian traffic. In installations where it
is known that pedestrians will be nearby
ensure a pedestrian door is available for
entrance and exit to the building. In
addition YOU MUST install an auxiliary
entrapment protection device (reversing
door edge or photoelectric beam device) as
part of the compete operator system.
ITEM # PART# DESCRIPTION QUAN.
1 Operator Power Head 1
2 005031 3 Button Station 1
3 009062 30 Tooth Sprocket, 1” Bore, 1/4 Key 1
4 009061 20 Tooth Sprocket, 1” Bore, 1/4 key 1
5 105193 Release/Hand Chain Wall Bracket 1
—— AR - As Required
ITEM # PART# DESCRIPTION QUAN
6 100413 1/4” Square Key 2
7 006119 5/16-18 x 1 Square Head Set Screw 4
8 009249 Release Chain AR
9 100315 #3 Hand Chain - Precut to 26 Ft. 1
10 009239 Drive Chain to Door Shaft, 4 Ft. 1
Connect an auxiliary entrapment protection
device (reversing edge or photoelectric
device across the door opening). A device of
this type is STRONGLY ADVISED FOR
ALL commercial operator installations. An
auxiliary entrapment protection device is
REQUIRED when the three button control
station is out of sight of the door or any
other automatic or manual control is used.
Install the opener at least 8 feet or more
above the floor.
Do not connect the opener to the source of
power until instructed to do so.
Locate the control station:
a) within sight of the door and;
b) at a minimum height of five feet above
the floor and;
c) away from all moving parts of the
door.
Do not overtighten the clutch adjustment to
compensate for a poorly working door.
Securely attach any WARNING signs or
placards to either the door or above the
control station as directed.
After installing the opener, all safety
features must be tested for proper operation
(see page 18).
IMPORTANT INSTALLATION NOTES
COMPONENT IDENTIFICATION LISTING
5