INSTALLATION INSTRUCTIONS - ELECTRICAL WIRING
TO AVOID DAMAGE TO DOOR AND
OPERATOR ENSURE ALL DOOR LOCKS ARE
DISABLED.
USE AN INTERLOCK SWITCH IF A LOCK IS
REQUIRED TO RETAIN FUNCTIONALTY.
CAUTION
RISK OF ENTRAPMENT THAT MAY
RESULT IN SERIOUS PERSONAL INJURY OR
DEATH. DISCONNECT POWER TO THE
OPENER BEFORE AND DURING
INSTALLATION OF AN ACCESSORY
REVERSING DOOR EDGE OR
PHOTOELECTRIC DEVICE. DO NOT
RECONNECT POWER TO OPENER UNTIL
INSTRUCTED TO DO SO. ENSURE DOORWAY
IS CLEAR BEFORE STARTING TESTING OF
UNIT.
WARNING
TO PREVENT THE RISK OF PERSONAL INJURY
AND/OR DAMAGE TO DOOR OR PROPERTY,
ONLY OPERATE DOOR CONTROL WHEN
DOOR IS IN CLEAR VIEW. IF CONTROL
STATION CANNOT BE LOCATED WHERE THE
DOOR IS VISIBLE OR IF ANY OTHER DEVICE IS
USED TO CONTROL THE DOOR AN AUXILIARY
ENTRAPMENT DEVICE (DOOR EDGE OR
PHOTOELECTRIC) MUST BE CONNECTED.
WARNING
TO PREVENT THE RISK OF PERSONAL INJURY
OR DEATH :
• DISCONNECT POWER AT THE FUSE BOX
BEFORE PROCEEDING.
• ELECTRICAL CONNECTIONS MUST BE MADE
BY A QUALIFIED INDIVIDUAL.
• OBSERVE LOCAL ELECTRICAL CODES WHEN
WIRING THE OPERATOR.
WARNING
WARNING: Allstar's MS Series operators have been designed and
constructed for use with 115 Volts AC single phase, see Figure 7
below. Check the operator nameplate label on the control box
cover for the proper voltage and phase. The application of an
improper input voltage or phase will result in catastrophic failure
to the internal electrical components.
Observe local electrical codes when wiring the operator.
When hard wiring, observe state and local electrical codes. A
wiring diagram is attached to the inside of the control box cover.
Connect the appropriate voltage and phase power leads to the
appropriate terminals as per the wiring diagram and connect a
ground wire to the grounding screw.
The wiring diagram attached inside the cover of the control box
details all of the field wiring terminal connections for the operator.
Always connect the wires to the push-button controls and auxiliary
devices exactly as shown.
Warning: Control voltage of the operator is 5 volts DC, Class 2.
Do not run the power leads and control circuit wiring in the same
electrical conduit.
Note: MS Series model operators are pre-wired for door
reversing edge components. To comply with code requirements,
the door reversing edge components must be installed and wired
to the operator. Refer to Figure 8 Door Edge component
installation and Figure 9 for Door Edge and photoelectric device
wiring.
If an Allstar Safe-Finish™ or Access Alliance Safe-Finish II™
photo-beam is connected and the photo-beam detects an
obstruction or becomes inactive, an opening door continues to
open and a closing door stops, pauses and starts open. While in
this mode, if a problem is detected while the operator is stopped,
a close will require constant activation. If the photo-beam is
attached and is properly working for 1 second, it will be auto
detected and the monitored function will be turned on. Once the
monitoring function is active, it will remain active even if the
power is removed and the photo-beam is disconnected and power
is restored. While in this mode, if a problem is detected while the
operator is stopped, a close will require constant activation.
Operators which are equipped with a reversing edge circuit may
have one or more additional means of control which should be
wired in accordance with the diagram supplied in the operator
and also illustrated in Figures 10 & 12. To add a second three
button station, refer to Figure 11.
Number 22 gauge wire or heavier must be used for wiring the
control stations and auxiliary control devices to the operator.
Smaller gauge wire may cause operational problems, especially
when multiple push-button stations are used or during summer
months.
10
115 VAC
Single
Phase
L1
L2
Ground
Figure 7 - Power
Connections