14 Invert Panel Outputs
When programmed as “Yes"” the three panel
outputs on the control panel switch from 0V to
+12V when active (+ve applied). When
programmed as “No” the outputs on the
control panel switch from +12V to 0V when
active (+ve removed). (Default = No)
15 Allow Set with AC Off
When programmed as “Yes”, the system can
be s et wit h no ma ins p ower. W hen
programmed as “No”, the system cannot be
set with no mains power. (Default = No)
16 Tamper Engineer Reset
When programmed as “Yes" the any tamper
alarm will require resetting by the engineer or
remote reset. When programmed as ”No"
tamper alarms can be reset by the user.
(Default = No)
17 Enable Jamming Detection
When programmed as “Yes" radio jamming
detection is enabled. When programmed as
”No” radio jamming detection is disabled , see
page 4 for details of jamming. (Default = Yes)
Goto User Menu 1 [1.0]
This option allows the engineer to access “User
menu 1", the flowchart below shows the options
within ”User menu 1", for full details refer to the
"Operators Manual".
32
Engineer’s Menu 1 TS690R Installation Manual
to alternate Yes and No
9
B
Enter configuration No.
e.g. 07 for user reset
E / MENU 1
CONFIG--
07- YES
07- NO
Configuration Flowchart
1
2
3
4
5
7
8
0
0
A
B
C
Bell Test
Walk Test
Remote
Reset
Change
code
Enable
Chime
Omit
Circuits
Silent Set
Full Set
Part Set A
Part Set B
Part Set C
SOUNDER 9
WALK TST
SAY ????
NEW ----
ENABLED
0 1- ARM ED
SIL SET
EXIT 999
EXIT 029
EXIT 029
EXIT 029
OPEN
U / MENU 1
E / MENU 1
User Menu 1 Flowchart