PROBLEM
CAUSE
CORRECTION
Fasteners are not the correct
size.
See specification and
fastener sections for correct
fastener information.
Fasteners are
jammed in tool
Air pressure regulated too
high
Adjust air pressure to the
correct PSI, see
specifications.
Brad
Nailer/Stapler
misfires or
sinks two
nails/staples at
the same time
Sluggish
operation
Loose drive guide screws Tighten screws.
Tool does
nothing
Air supply inadequate
Check PSI and CFM
Week drive
Tool fails to drive
fastener
Inadequate air flow or
pressure to tool.
Check air flow and pressure
to tool.
Fasteners are bent Replace with undamaged
fasteners.
Air supply inadequate
Check PSI and CFM
Tool runs slow
or has loss of
power
Tool not lubricated
sufficiently.
Tool needs to be lubricated.
Inadequate air flow or
pressure to tool.
Check air flow and pressure