![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/cc/dcc780e2-02d8-4d73-ad47-dca17d60a0c3/dcc780e2-02d8-4d73-ad47-dca17d60a0c3-bg33.png)
2. Programming Concepts
2-19
Special
M
Function
ES2
EX2
SS2 SA2 SX2
OFF
Ø
ON
STOP
Ø
RUN
RUN
Ø
STOP
Attrib.
Latch
-ed
Default
M1052 Disable interruption I200 / I201
○ ○ ○ ○
OFF - - R/W NO OFF
M1053 Disable interruption I300 / I301
○ ○ ○ ○
OFF - - R/W NO OFF
M1054 Disable interruption I400 / I401
○ ○ ○ ○
OFF - - R/W NO OFF
M1055 Disable interruption I500 / I501
○ ○ ○ ○
OFF - - R/W NO OFF
M1056 Disable interruption I600~I699
○ ○ ○ ○
OFF - - R/W NO OFF
M1057 Disable interruption I700~I799
○ ○ ○ ○
OFF - - R/W NO OFF
M1058 COM3 monitor request
○ ╳ ○ ○
OFF - - R/W NO OFF
M1059
Disable high-speed counter interruptions
I010~I080
○ ○ ○ ○
OFF - - R/W NO OFF
M1060 System error message 1
○ ○ ○ ○
OFF - - R NO OFF
M1061 System error message 2
○ ○ ○ ○
OFF - - R NO OFF
M1062 System error message 3
○ ○ ○ ○
OFF - - R NO OFF
M1063 System error message 4
○ ○ ○ ○
OFF - - R NO OFF
M1064 Incorrect use of operands
○ ○ ○ ○
OFF OFF - R NO OFF
M1065 Syntax error
○ ○ ○ ○
OFF OFF - R NO OFF
M1066 Loop error
○ ○ ○ ○
OFF OFF - R NO OFF
M1067* Program execution error
○ ○ ○ ○
OFF OFF - R NO OFF
M1068* Execution error locked (D1068)
○ ○ ○ ○
OFF - - R NO OFF
M1070
Switching clock pulse of Y1 for PWM
instruction (ON: 100us; OFF: 1ms)
○ ○ ○ ○
OFF - - R/W NO OFF
M1071
Switching clock pulse of Y3 for PWM
instruction (ON: 100us; OFF: 1ms)
○ ○ ○ ○
OFF - - R/W NO OFF
M1072 PLC status (RUN/STOP), ON = RUN
○ ○ ○ ○
OFF ON OFF R/W NO OFF
M1075
Error occurring when write in Flash ROM
○ ○
○ ○
OFF - - R NO OFF
M1078
Y0/CH0(Y0, Y1) pulse output pause
(immediate)
○ ○ ○ ○
OFF OFF - R/W NO OFF
M1079
Y1 pulse output pause (immediate)
○ ○ ○ ○
OFF OFF - R/W NO OFF
M1080 COM2 monitor request
○ ○ ○ ○
OFF - - R/W NO OFF
M1081
Changing conversion mode for FLT
instruction
○ ○ ○ ○
OFF - - R/W NO OFF
M1083*
Selecting X6 pulse-width detecting mode.
M1083 = ON, detecting pulse-width when
X6 = ON; M1083 = OFF, detecting pulse-
width when X6 = OFF.
○ ○ ○ ○
OFF - - R/W NO OFF
M1084*
Enabling X6 Pulse width detecting
function. (has to be used with M1183 and
D1023)
○ ○ ○ ○
OFF OFF OFF R/W NO OFF
M1085
Selecting DVP-PCC01 duplicating function
○ ○ ○ ○
OFF - - R/W NO OFF