pprrooggrraammmmiinngg
Programming options control what your system does during
normal operation, and require few or no additional parts.
However, some may require additional installation labour.
The following is a list of the program settings, with the factory
settings in
BBoolldd::
AAccttiivvee aarrmmiinngg
(only with the transmitter) or passive arming (au-
tomatic arming 30-seconds after the last door has been closed).
Arming/disarming confirmation siren chirps
oonn
or off.
The ignition controlled door lock feature on or
ooffff
: With
this feature on, the doors will lock three seconds after the
ignition is turned on, and the doors closed. The system will
not lock the doors when the ignition is turned on with any
door open.
Ignition controlled door unlock on or
ooffff
. With this feature
on the doors will unlock when the ignition is turned off.
Passive door locking (with passive arming) or
aaccttiivvee ddoooorr
lloocckkiinngg
(only when arming with the transmitter). Passive
locking allows the vehicle's doors to lock when the security
system passively arms (after the 30 second countdown). This
feature only works if passive arming has been programmed on.
Forced passive arming on or
ooffff
: If your system is
programmed for passive arming and the forced passive
arming feature has been programmed on, the system will
passively arm after one hour, even if a protected entry has