18 USSC
Error
Code
Err1
Err2
Err3
Err4
Err5
Err6
Err7
Err8
Error
Descrption
Thehighlimittemperaturesensor
hastripped.
Stoveranoutoffuelduringnormal
operation.
The stove was unable to reach the
RoomFanOntemperaturewithinthe
startuptime.
Thepowerfailedwhilethestovewas
hot, and when power was restored,
therewasout.
TheAugeroutputfusehasblown.
TheIgnitoroutputfusehasblown.
The Draft Fan (Exhaust Fan) output
fusehasblown.
TheRoomFanoutputfusehasblown.
Possible
Causes
• Inadequateventilation.
• Roomfanfailure.
• ExhaustBlockage.
• ElectricalOpenintheovertemperatureswitchorwiring.
• HopperEmpty.
• Augeroutputfailureorjam.
• Flameoffuelqualitycausedretoburntooslowlyorgoout.
• ElectricalOpeninlowtemperatureswitchorwiring.
• FlameorFuelqualitycausedtheretoburntooslowlyorgo
out.
• AugeroutputfailureorjamHopperemptyonstartup.
• ElectricalOpeninlowtemperatureswitchorwiring.
• Powerloss
• Augermotorjammedorbad.
• Ignitorshortedoutorbad.
• DraftFanmotorjammedorbad.
• Roomfanmotorjammedorbad.
Severalsituationsoreventsareindicatedinnormaloperationbyblinkingdisplayindicatorsorsegmentsinthedisplay:
Thismeansthatthestoveisinthe“StartUp”statewaitingforeithera3minutetimeouttobegin
burningorforthestovetoreachthewarmtemperaturewhichevercomesrst.
Thisindicatesthatthestoveisinthe“Shutdown”statewaitingfortheOFFbutton,orfora15
minuteperiodafterthestovewasturnedoff,orforthestovetocooldown,orforthedoortobeclosed.
Thisindicatesthatthestoveisinthenormalrunmodeandisrampingfrom
thecurrentheatrangesettingtothetargetheatrangesetting.Oncetherampiscomplete,thedashwillstopashing.
Forrampingfromheatrange1to5,thedefaulttimeis12minutes(witha90secondramptime).
Thisindicatesthatthestoveisinnormaloperationandisrunningintheautomatic
mode.However,eithertheDraftFanorAuxiliarysettingismanuallycongured.
Thisindicatesthatthestoveisinnormaloperationandthatthevacuumsensor
detectsalossofpressureeitherbecausethedoorisopenorbecausethereisanegativepressureintheroomwith
respecttotheexhaust.
Thisindicatesthattheignitorisonduringthelightingstage.
Thisindicatesthatthestoveisin
normaloperationandthatanovertemperatureconditionexistscausingthefueltostop.
Thisindicatesthatthestoveisinacut
backconditioninanattempttopreventanovertemperatureshutdown.
Toreturnthecontroltoitsoriginalfactorydefaultsettings,pressandholdtheAUXUPandAUXDOWNbuttonstogether
forthreeseconds.