United States Stove 5500 Remote Starter User Manual


 
14 USSC
SHUT DOWN PROCEDURE
Pressthe“OFF” buttononthecontrolpadtoputthestoveinshutdownmode.Atthistime,theredlightabovethepad
willilluminate.Oncethisisdone,theaugerwillstopfeedingpellets,butthedistributionblowerandexhaustblowerwill
continuetooperate.Whentheinternaltemperatureoftheunitdropsbelowthefactorypresettemperature,thedistribution
blowerandexhaustblowerwillceasetooperate.Theredlightwillthenshutoffandtheunitwillbecompletelyshutdown.
Thehottertheunitisduringitsoperation,thelongeritwilltakeforthestovetocompletetheshutdowncycle.Ifthe
stovestaysonformorethan2hoursafterpressingthe“OFF” buttonandyouaresurethatthereisout,thestovecan
beunpluggedfromtheoutlet.Afterapproximately10seconds,theunitcanbere-connectedtothepowersourceand
thecontrolboardwillbereset.
Operation
START-UP PROCEDURE


Verifythatthehopperiscleanandfreeofforeignmatter.
Verifythatalloftherequiredexhaust/inletconnectionshavebeenmadeinaccordancewiththismanualandthat
thestoveispluggedintoanoutlet(anoutletsurgeprotectorishighlyrecommended).
Fillthehopperwithwoodpellets;donotallowanypartofthebagoranyotherforeignmaterialintothehopper,as
thismayjamtheauger.
Ensurethatallpelletmatterisclearedfromthehopperseatingsurface.
Closethehopperlid.
Makesurethattheviewingdoorissecurelyclosed(thesafetypressureswitchwillnotallowthestovetofeedfuel
ifthereisnodraftpressureinsidethestove).
Pressthe“ON” buttononthecontrolpadandsetthe“HEAT SETTING” toyourdesiredsetting.
Thestovewillbegintofeedfuelandthewillignitethefuelinapproximately5minutes.
Onceaconsistentamehasbeenestablished,youcanadjustthe“HEATRANGE”and“BLOWERSPEED”onthecon-
trolpadtoyourdesiredsettings.(Note:Thedistributionblowerwillnotfunctionuntiltheheatexchangerinthestove
reachesthefactorypresettemperature).
1.)
2.)
3.)
4.)
5.)
6.)
7.)
8.)
Adjustthe“HEAT RANGE” and“BLOWER SPEED” toa“3” settingandallowthestove
tooperateinthismannerforapproximatelythree(3)hours(ormoreifnecessary),allowingthestoveto
“cureout”asthepaintandoilsfromthemanufacturingprocessburnoff.Werecommendthatyouopen
doorsandwindowsinyourhomeduringthisprocess.Adjustsettingtodesiredsetting.
