United States Stove 5500 Remote Starter User Manual


 
USSC 13
UNIT PREPARATION
Aftercarefullyunpackingandreadingtheinstructionsforinstallingyourstove,youwillneedtoperformthefollowingsteps:
Attachtheincludedspringhandletothedoorhandlebyscrewingitoninarespectivelocation.
Attachtheelectricalcordtothebackofthestoverst;thenplugitintoa110-voltoutlet(anoutletsurgeprotectoris
highlyrecommended).
PERFROMING AN INTIAL TEST
Thistestisusedatthefactorywherethestovesareassembledtotestthefunctionalityofthecontrolandthestove
beforetheunitisshipped.Toperformthistest,pressandholdtheOFFandAUGERDELAYbuttonssimultaneouslyfor
3seconds.Toadvancethroughthetest,pressanykeyunlessotherwisenotedintheteststep.
ExhaustFanOutputTest–Thedisplaywillshow“drft”.Theexhaustfanisturnedonfullthenreducedtoaleveljust
abovethetypicalminimumpressureswitchsetting.TheONLEDindicateswhetherthepressuresensorisdetected.
Ifthepressureswitchisnotdetected,thefanrampstofullonfortwosecondsthenreturnstothepreviouslyestablished
levelifthepressureswitchcloses.IftheDraftFanFuseisnotblownandthefusedetectioncircuitisfunctioning,
theDraftFanLEDwillbelitandtheotherthreetoprowLEDswillbeoff.
RoomFanOutputTest-Thedisplaywillshow“rfan”.Theroomfanisturnedonfull.IftheRoomFanFuseisnot
blownandthefusedetectioncircuitisfunctioning,theRoomFanLEDwillbelitandtheotherthreetoprowLEDs
willbeoff.
IgnitorOutputTest-Thedisplaywillshow“ignt”.Theignitormotoristurnedonfull.IftheIgnitor(AUX)Fuseisnot
blownandthefusedetectioncircuitisfunctioning,theAuxLEDwillbelitandtheotherthreetoprowLEDswillbeoff.
AugerOutputTest-Thedisplaywillshow“augr”.Theaugermotoristurnedonfull.IftheAugerFuseisnotblown
andthefusedetectioncircuitisfunctioning,theHeatRangeLEDwillbelitandtheotherthreetoprowLEDswillbeoff.
HopperSwitchTest–Thedisplaywillshow“hppr”.The“ON”LEDislit.Ifthehopperswitchisopen(lidisopen),
the“HEATRANGE”LEDwillturnon.Ifthelidisclosed,the“HEATRANGE”LEDwillbeoff.
ThermostatInputTest–Thedisplaywillshow“stat”.Ifthethermostatinputisclosed,theONLEDwillturnon,
otherwiseitwillbeoff.
FluegasThermistorTest–ThedisplaywillshowtheuegastemperatureindegreesF.
ACFrequencyTest-DisplaysthemeasuredACFrequencyinhertzfollowedbytheletter‘H’.
WatchdogReset–Thewatchdogtimeristestedtoensurethattheboardcanbereset.Themessage“BYE”is
displayeduntilthewatchdogresetstheboard.
Operation
1.)
2.)
3.)
4.)
5.)
6.)
7.)
8.)
9.)
PERFORMING A “DRY RUN”
Performa“dryrun”onyourstovepriortomakingtheexhaust/inletconnectionsandstartingyourstoveforthersttime.
CheckthatthereisNOfuelorANYforeignmaterialinthehopperorburn-pot.
Checkthattheviewingdoorandhopperlidissecurelyclosed.
Pressthe“ON”buttononthecontrolpanel.VerifythattheONLEDislit(blinking)andthedisplayshowsHR-1.Also
theLEDabovetheHEATRANGEandtheAUTOMODEindicatorshouldbelit.IfanyotherLED’sarelitorashing,
consultthe“DisplayIndicators”inthismanual.
Youshouldheartheexhaust(draft)fanrunningimmediatelyandtheaugershouldbeginturningcontinuouslyfor1
minute.
Theautofuelignitor(locatedinsidethebackwalloftheburnpot)shouldbegintoglowred/orangeafter3minutes.
TheRoomFanwillnotoperateatthistimesincetheunitmustreachafactorypresettemperature.
DONOTopentheviewingdoor,thewillgetveryhotduringthistest.Thestovewillautomatically
shutdownafterapproximately23minutes.
1.)
2.)
3.)
4.)
5.)
6.)