Scytek electronic 8000 Automobile Alarm User Manual


 
Page 16 VisionGaurd 8000
1. Thoroughly read and become familiar with the installation instructions before beginning the installation.
2. Review system contents:
Main Unit
One 5-Button one-way Remote Transmitter
One 4 Button two-way Remote Transmitter
Siren
Shock Sensor
Harnesses
6-Pin starter harness
20-Pin main harness
4-Pin shock sensor harness
3-Pin door lock harness
LED harness
Override Switch harness
3. Verify vehicle is equipped with electronic fuel injection, and starts/idles normally before installation.
4. Determine if vehicle is equipped with a factory theft deterrent system and obtain proper bypass module
if required.
5. Find a location to mount the hood pin switch that will not interfere with the opening of the hood, and
is not in a position that can accumulate water. The hood pin is a safety device that must be installed
to avoid remote starting during engine servicing.
6. Verify with the owner, the mounting locations for all visible components, including the LED and Override
switch.
7. Verify with the owner, the optional features of the VisionGuard 8000 and the features that must be
programmed during installation.
8. Inspect and perform a function test of all vehicle systems before and after the installation.
9. Always use a Volt / Ohm meter for testing vehicle circuits. Never use a test light.
10. Always look before drilling any holes or mounting self-tapping screws. Be sure fuel lines and exterior
wiring looms are clear as they are often close to the chassis and difficult to see.
11. Protect all wires running from the engine compartment to the interior of the vehicle by covering with
electrical tape and split loom tubing. Be sure to use a grommet when routing wires through the
firewall.
12. Properly fuse any additional accessories such as window modules, door lock actuators, etc., making
sure to power them separate from the alarm module. This will ensure the functionality of the security
system in the event of an accessory failure.