OPERATION
1. Before attempting to start the power buggy, make sure
that the safety kill switch (Figure 19) is not pushed
in. The power buggy will not start with the kill switch
engaged.
2. Pull the choke knob out to the CLOSED position
(Figure 8).
Figure 8. Choke Knob (Closed Position)
3. Move the throttle lever halfway between the FAST and
SLOW position (Figure 9) for starting.
Figure 9. Throttle Lever (Fast Position)
attempt to operate the power
buggy until the Safety Information, General
Information, and Inspection sections of this
manual have been read and thoroughly
understood.
NOTICE
The CLOSED position of the choke lever enriches
the fuel mixture for starting a cold engine. The OPEN
position provides the correct fuel mixture for normal
operation after starting, and for restarting a warm
engine.
4. Insert the ignition key into the ignition switch (Figure 10).
Turn the key to the ON position then to the START
position. Release the key when the engine starts.
Figure 10. Ignition Switch
5. Push the choke knob inward slowly to the OPEN
position (Figure 11) before operating the power buggy.
Before the buggy is placed into operation, run the
engine for several minutes. Check for fuel leaks, and
noises that would associate with a loose guard or cover.
Figure 11. Choke Knob (Open Position)
1. Follow steps 1 through 3 of the Electric Start procedure.
2. Insert the ignition key into the ignition switch (Figure 10),
turn the key to the ON position.
3. Grasp the starter grip (Figure 12) and slowly pull it
out. The resistance becomes the hardest at a certain
position, corresponding to the compression point. Pull
the starter grip briskly and smoothly for starting.
Figure 12. Starter Grip