Multiquip G-55H Automobile Parts User Manual


 
G-55H GASOLINE VIBRATOR — OPERATION & PARTS MANUAL — REV. #0 (03/07/06) — PAGE 17
Figure 11. Engine ON/OFF Switch (OFF Position)
3. Close the
fuel shut- off valve
(Figure 12) by moving the
fuel valve lever to the OFF position.
Figure 12. Fuel Valve Lever (OFF Position)
Stopping The Engine
1. Move the throttle lever to the IDLE or SLOW position
(Figure 11) and run the engine for three minutes at low
speed.
2. After the engine cools, turn the engine
start/stop switch
to the OFF position (Figure 11).
7. If the engine has started, slowly return the choke lever
(Figure 6) to the OPEN position. If the engine has not
started repeat steps 1 through 6.
8. Before the vibrator is placed into operation, immerse the
vibrator head into the concrete and run the engine for
several minutes. Check for fuel leaks, and noises that
would associate with a loose V-belt cover or component.
G-55H GASOLINE VIBRATOR — START-UP/SHUTDOWN PROCEDURES
The vibrator head is cooled by the concrete. Operation
of the vibrator head in air longer than 2 minutes will
cause overheating of the bearings which result in
premature head failure.
CAUTIONCAUTION
CAUTIONCAUTION
CAUTION
Vibrator Head
Overheating Hazard
9. To begin use, move the throttle lever (Figure 6) toward the
FAST position.