BEFORE YOU DIVE WITH SPARE AIR
• SPARE AIR shipped empty - fill prior to use.
SPARE AIR is always ON and ready for use. The White Pressure
Indicator Pin should extend flush with the top of the Pressure
Indicator Gauge indicating that the unit is full. (The optional Dial
Gauge indicator will show full when dial is at “3”.) If Pressure
Indicator Pin is less than flush SPARE AIR MUST be refilled. Do not
dive until you have refilled SPARE AIR. See refilling instructions on
page 12.
Push Purge Button down and release. Purge Button should move
up and down freely. To maintain full pressure in SPARE AIR do not
use purge unnecessarily.
Make sure SPARE AIR is mounted firmly and adjusted properly in
Holster before entering the water. Velcro must be fully engaged.
NOTE: For added security a safety leash/lanyard is
recommended so that SPARE AIR is not lost if it is dislodged,
dropped or released by accident. Hold SPARE AIR secure
with a free hand on entry into the water or in rough surf or
currents.
HOW TO MOUNT SPARE AIR
1. Determine where on BC you would like to mount SPARE AIR.
Look for an area that has 2 places to attach the Quick
Disconnect Straps (on D-rings, Straps, etc.)
2. The Straps are movable by threading them through any of the
webbing sections on back of Holster. Choose the 2 that would
allow for the tightest fit possible.