Connection diagrams:
BROWN
BLUE
M
Basic actuator -
Fig.1 : 35xxxxx00xxxxx
Electrical installation
Be aware of BUS actuator - please see the installation guide.
Motor connection
Wiring: The actuator direction (forward, reverse) is controlled with a doublethrow
switch with the centre postion “off”.
Motor
+
Actuation
To extend the actuator, connect brown to positive and blue to negative.
To retract the actuator, connect blue to positive and brown to negative.