Linak LA35 Automobile Parts User Manual


 
Mounting guidelines
LINAK
®
linear actuators are quickly
and easily mounted by slipping pins
through the holes on each end of
the units and into brackets on the
machine frame and the load.
The mounting pins must be parallel
to each other as shown in Figure 1.
Pins, which are not parallel to each
other, may cause the actuator to
bend and be damaged.
The load should act along the stroke
axis of the actuator since off centre
loads may cause bending and lead to
premature failure. See Figure 2.
Make sure the mounting pins are
supported in both ends. Failure to
do so could shorten the life of the
actuator. Cantilever mounts are
unacceptable.
Figure 1
Figure 2
X
X
RIGHT WRONG
WRONG
Warning!
If the actuator is used for pull in an application where personal
injury can occur, the following is valid:
It is the application manufacturer’s responsibility to incorporate a suitable
safety arrangement, which will prevent personal injury from occurring, if
the actuator should fail.
Warning!
LINAK’s actuators are not constructed for use within the following
fields:
Offshore installations
Aeroplanes and other aircraft
Explosive environments
Nuclear power generation
10