Giant P300 Automobile Parts User Manual


 
5
Specifications
Model P317
NOTES:
In order to drive the pump from the side opposite the present shaft
extension, simply remove the valve casing from the crankcase and
rotate the pumps 180 degrees to the desired position. Be certain to
rotate the seal case (item #20) as well, so that the weep holes are
down at the six o'clock position. Exchange the oil fill and the oil
drain plugs, also. Refer to the repair instructions as necessary for
the proper assembly sequence.
Consult the factory for special requirements that must be met if the pump is
to operate beyond one or more of the limits specified above.
HORSEPOWER RATINGS:
The rating shown are the power
requirements for the
pump. Gas
engine power outputs must be
approximately twice the pump
power requirements shown above.
We recommend a 1.15 service factor
be specified when selecting an
electric motor as the power source.
To compute specific pump horse
power requirements, use the
following formula:
HP = (GPM X PSI) / 1450
SPECIAL NOTE:
The theoretical gallons per revolution
(gal/rev) is 0.00205.
To find specific outputs at various RPM,
use the formula: GPM = 0.00205 x RPM
*Intermittent duty
P317 HORSEPOWER REQUIREMENTS
RPM GPM
1000
PSI
1500
PSI
2000
PSI
2500
PSI
3000
PSI
3500
PSI*
975 2.0 1.4 2.1 2.8 3.4 4.1 4.8
1220 2.5 1.7 2.6 3.4 4.3 5.2 6.0
1464 3.0 2.1 3.1 4.1 5.2 6.2 7.2
1700 3.5 2.4 3.6 4.8 6.0 7.2 8.4
1800 3.7 2.5 3.8 5.1 6.4 7.6 8.9
U.S. (Metric)
Volume............................................................ 3.7 GPM ................... (14.0 LPM)
Discharge Pressure (Continuous) ................... 3000 PSI................... (200 bar)
Discharge Pressure (Intermittent) ................... 3500 PSI................... (240 bar)
Inlet Pressure ..................................................................................... Up to 90 PSI
Stroke.............................................................. 0.42”......................... 10.6 mm
RPM................................................................................................... Up to 1800 RPM
Plunger Diameter ............................................ 0.71”......................... 18mm
Temperature of Pumped Fluids ...................... Up to 160
o
F ............. (71
o
C)
Inlet Ports........................................................................................... (2) 1/2" BSP
Discharge Ports.................................................................................. (2) 3/8" BSP
Shaft Rotation ................................................. Top of pulley towards manifold
Crankshaft Diameter.......................................................................... 24mm
Key Width.......................................................................................... 8mm
Shaft Mounting .................................................................................. Either side
2
Weight............................................................. 16 lbs. ............................... (7.26 kg)
Crankcase Oil Capacity .................................. 14.2 fl.oz. ......................... (0.42 liters)
Extended Crankcase Oil Capacity .................. 17 fl. oz. ........................... (0.5 liters)
NPSHR (@ 1450 RPM) .................................................................... 26.2 ft of water - 8.0 mW