Giant P300 Automobile Parts User Manual


 
P340 HORSEPOWER REQUIREMENTS
RPM GPM 1500 PSI 2000 PSI 2500 PSI 3000 PSI 3500 PSI 4000 PSI*
745 1.5 1.6 2.1 2.6 3.1 3.6 4.1
1025 2.0 2.1 2.8 3.4 4.1 4.8 5.5
1340 2.7 2.8 3.7 4.7 5.6 6.5 7.4
1450 2.9 3.0 4.0 5.0 6.0 7.0 8.0
1750 3.5 3.6 4.8 6.0 7.2 8.4 9.7
10
Specifications
Model P340
Consult the factory for special requirements that must be met if the pump is
to operate beyond one or more of the limits specified above.
NOTE:
1 In order to drive the pump from the side opposite the present shaft extension, simply
remove the valve casing from the crankcase and rotate the pumps 180 degrees to the
desired position. Be certain to rotate the seal case (item #20) as well, so that the
weep holes are
down at the six o'clock position. Exchange the oil fill and the oil drain
plugs, also. Refer to the repair instructions as necessary for the proper assembly
sequence.
HORSEPOWER RATINGS:
The rating shown are the power
requirements for the
pump. Gas
engine power outputs must be
approximately twice the pump
power requirements shown above.
We recommend a 1.15 service factor
be specified when selecting an
electric motor as the power source.
To compute specific pump horse
power requirements, use the
following formula:
HP = (GPM X PSI) / 1450
SPECIAL NOTE:
The theoretical gallons per revolution
(gal/rev) is 0.00201.
To find specific outputs at various RPM,
use the formula: GPM = 0.00201 x RPM
U.S. (Metric)
Volume ............................................................ Up to 3.5 GPM ......... (13.2 LPM)
Discharge Pressure (Continuous) ................... Up to 3500 PSI......... (240 bar)
Discharge Pressure (Intermittent)................... Up to 4000 PSI ......... (275 bar)
Inlet Pressure ..................................................................................... Up to 90 PSI
Stroke.............................................................. 0.55”......................... 14.1mm
RPM................................................................................................... Up to 1750 RPM
Plunger Diameter ............................................ 0.63”......................... 16mm
Temperature of Pumped Fluids ...................... Up to 160
o
F ............. (71
o
C)
Inlet Ports........................................................................................... (2) 1/2" BSP
Discharge Ports.................................................................................. (2) 3/8" BSP
Shaft Rotation ................................................. Top of pulley towards manifold
Crankshaft Diameter.......................................................................... 24mm
Key Width.......................................................................................... 8mm
Shaft Mounting .................................................................................. Either side
1
Weight............................................................. 16 lbs. ....................... (7.26 kg)
Crankcase Oil Capacity .................................. 14.2 fl.oz. ................. (0.42 liters)
Extended Crankcase Oil Capacity .................. 17 fl. oz. ................... (0.5 liters)
*
Intermittent duty