Furuno FCV-1200L Radar Detector User Manual


 
5-3
5.3 Troubleshooting
This section provides simple troubleshooting procedures which the user may follow to restore
normal operation.
If… Then…
there are no echoes but the scale appears
check if the transducer is properly connected.
there is no zero line or zero line is not in correct
position
check if the range shifted. (Zero line does not
appear when the range is shifted.)
press the [-] key so as the scale appears from
0.
you suspect low sensitivity
check that gain control is properly set.
the bottom is traced in zigzag pattern or you
experience occassional loss of echo
the sea may be rough. Bottom is traced zigzag
when the sea is rough.
own boat may have passed over other boat’s
wake, which blocks propagation of sound wave.
there is no depth readout
check to see if bottom is present on the normal
picture range.
check if bottom echo is strong enough (red,
reddish brown in color).
automatic shift is inoperative
check if bottom echo is strong enough (red,
reddish brown in color)
picture is distorted
check if magnetic field generating equipment
(transformer, rectifier) are nearby.
color is strange in a given area
check if a magnet is near the equipment.
occasional noise is seen
check if the cables of pulse generating
equipment are near the equipment.
there is noise and interference
check that GAIN and CLUTTER properly
adjusted.
check the setting of the noise limiter.
check the equipment’s ground.