4.0 Before You Run Your Vehicle Using Your Edelbrock Nitrous System
You have just completed the installation of your Edelbrock Nitrous System. It is time to perform some basic system checks
to ensure all of the work you have done is correct and ready to operate properly. The following procedure is designed to
validate the operation of your nitrous system before operating your vehicle:
Note: Before performing steps 1 through 4, make sure that the nitrous bottle is closed and main nitrous supply
line is empty of any nitrous.
4.1 Fuel System Check
1. Hook up all battery leads.
2. Double-check all wires and leads for signs of heat and proper connections.
3. Turn the ignition to the “on” position but do not start the engine.
4. Check all fittings for leaks.
5. Switch master arming switch to the “on” position (switch should now glow red). Make sure the nitrous
bottle is closed and the main feed line are completely empty of ANY nitrous! Standing by the engine
compartment, tap the microswitch and listen to hear the solenoids click open. If both solenoids are clicking,
the solenoids have been installed correctly. Wait a minimum of 30 minutes before starting the vehicle so as to
be sure that any fuel that was sprayed into the intake has time to evaporate.
4.2 Nitrous System Check
1. With the vehicle's engine running, slowly open nitrous bottle valve.
Note: There should be no change in engine idle speed. If idle speed changes, close nitrous bottle valve
immediately and refer to the "Troubleshooting Guide" section.
2. Inspect nitrous lines and fittings for leaks using a soapy water mixture and a small brush.
3. If any of the fittings/connections show bubbling around the attachment nut or on the threaded area of the
fitting, shut the nitrous bottle valve off immediately and dry the fitting before attempting any service to that
particular fitting connection.
4. If the engine idle does not come up, and all of the fittings appear to be leak-free, you have successfully
completed the installation of you Edelbrock Nitrous System.
5.0 Solenoid Inspection and Maintenance
1. Close valve on nitrous bottle.
2. Make sure all nitrous supply lines are free of pressure before removal of any system solenoid.
a. Empty main nitrous supply line at the nitrous bottle. Take care to not breathe or expose your skin to nitrous.
b. Do not open pressurized fuel lines over a hot engine.
3. Remove nitrous solenoid from the engine and securely clamp it into a vise, taking great care not to damage the solenoid.
4. Remove the solenoid cover, retaining nut from top of the nitrous solenoid.
5. Remove coil and housing from nitrous solenoid base.
6. Unscrew stem from nitrous solenoid base. Do this by using a solenoid stem removal tool or by “double nutting” the stem
and unscrewing the stem from the housing body. Do not use pliers on solenoid stem; damage to the stem will result.
7. Carefully remove the stem, spring and plunger from the solenoid base paying close attention to the way they are
assembled.
8. Examine the plunger seal for swelling, cuts and abrasions. The seal surface should be flat, except for a small circular
indentation in the center of the seal.
A seal that has been contaminated or over-pressurized will bulge from exposure to chemicals other than nitrous
oxide. It can appear to extend down from the plunger and be dome-shaped. A contaminated seal may return to its
original shape if left out in fresh air for approximately 48 hours. It may then be returned to service. If it does not return
to its original shape, it must be replaced.
9. Clean the solenoid body. Do not use an oil-based solvent to clean any part of the solenoid.
Use paint thinner
or electrical contact cleaner. Remove any contaminants that may be present. Make sure solenoid body is clean, dry
and free of oils before assembly.
10. Replace the O-Ring, plunger and piston spring.
11. Re-assemble solenoid by reversing disassembly procedure.