Auto Page RF-225 Automobile Electronics User Manual


 
5
IGNITION CONTROL DOOR LOCKS.
If the vehicle’s door locks have been interfaced to the security system, the
system will automatically lock the vehicle's doors when the ignition is turned
“ON” and /or unlock the vehicle’s doors when the ignition is turned “OFF”.
TRUNK RELEASE.
Press and hold
button on transmitter for three seconds to remote
control the trunk release or other electric devices.
CAR LOCATOR
Press the button on the transmitter when the vehicle is in the armed /
locked mode to active car locator function. The siren or horn will chirp 6
times. The parking light will flash 12 times, allowing you to easily locate
your car.
ADJUST AND TEST THE SENSITIVITY LEVEL OF THE SHOCK SENSOR
(OPTIONAL) If alarm option is installed.
1. Turn the Ignition 'switch ‘ON/OFF’ 3 TIMES and stay in the OFF position.
2. Push the Valet switch 8 times holding in on the 8th push until four chirps
with a long chirp is heard. Then release the valet switch. You are now in
the Alarm feature ‘Shock Sensor’ programming mode.
3. Press and hold button for 2 seconds. One long siren or horn chirp to
indicates the unit is ready to accept adjustments of the shock sensor.
4. Press button on the transmitter once. This will decrease the sensitivity
level by one step. Each time the button is pushed, a decrease is made the
siren /horn chirp will respond with [1] chirp, while 2 chirp indicates
minimum sensitivity.
5. Press button on the transmitter once. This will increase sensitivity level
by one step. Each time an increase is made the siren/horn chirp will
respond with [1] chirp, while 2 chirp indicates maximum sensitivity.
6. Hit the bumper or strong metal part of the vehicle to test the threshold level
of the sensor.
a). Activate the warn-away (first stage the shock sensor), the siren or horn
will emit a short chirp.
b). Activate the full alarm (second stage the shock sensor), the siren or
horn will emit a long chirp.
7. When you are satisfied with the setting, press the button to lock in the
adjustment. One long siren or horn or horn chirp will indicate the unit has
locked in the adjustment.
Note: If 30 seconds of inactivity expires, or you turn on the ignition during of
above steps, the unit will exit the program mode and return to the disarmed
mode. Three long chirps will confirm exit.
ALARM OPERATING CONDITION: (OPTIONAL) If alarm option is installed.
Function
Siren or
horn
Par
king
Lights
LED
Doors
Starter
Disable
Pager
Option
1. Arm
1 Chirp
1 Flash
Slow flash
Locking
On
2. Disarm
2or4
Chirps
2 or 3
Flashes
Off or
Fast flash
Unlocking
Off
3. Trigger
Alarming
Flashing
Slow flash
On
On
4. Panic
Alarming
Flashing
Slow flash
Locking
On