Black w/ White Trace Wire : 300 mA Horn Output
The black w/ white trace wire is provided to beep the vehicle’s horn. This is a transistorized low current
output, and should only be connected to the low current ground output from the vehicle’s horn switch.
If the vehicle usesa+12VDChorn switch, then connect the black w/ white trace wire to terminal 86 of the
AS 9256 relay ( or an equivalent 30 Amp automotive relay ), and connect relay terminal 85 to a fused + 12
VDC battery source. Connect relay terminal 87 to the vehicle’s horn switch output, and connect relay
terminal 30 to a fused + 12 VDC battery source.
Dark Green w/ Black Trace Wire : Latching Output / Channel 3
The green w/ black trace wire latches to ground via an independent RF channel from the keychain transmit-
ter. This is a transistorized, low current ( 300 mA ) output, and should only be used to drive an external relay
coil.
This wire provides an immediate ground signal, and stays at ground for as long as the button(s) on the
keychain transmitter remain pressed.
WARNING ! Connecting the dark green w/ black trace wire to the high current switched output of
trunk release circuits will damage the control module.
Connect the dark green w/ black trace wire to terminal 86 of the AS 9256 relay ( or an equivalent 30 Amp
automotive relay ), and wire the remaining relay contacts to perform the selected function of channel 3.
2 Pin Blue Connector : Valet Switch
Route the grey and black wires in the 2 pin connector from the valet switch to the control module, and plug
it into the mating blue connector on the side of the module.
2 Pin White Connector : Dash Mounted L.E.D.
Route the red and blue wires in the 2 pin white connector from the L.E.D. to the control module, and plug
it into the mating white connector on the side of the module.
4 Pin White Connector : Shock Sensor (OPTIONAL)
Route the red, black and green wires in the 4 pin white connector from the shock sensor to the control
module, and plug one end into the shock sensor, and the other end into the mating white connector on the
side of the module.
Red & Green 2 Pin White Connector : Door Lock Outputs
These wires will provide either a pulsed ground output to the factory door lock control relay, or a pulsed
+ 12 volt output to the factory door lock control relay. In either case, the maximum current draw through
these outputs must not exceed 300 mA.
3 Wire Ground Switched Door Locks
In this application, the red wire provides a ground pulse during arming, or the pulsed ground lock output.
Connect the red wire to the wire that provides a low current ground signal from the factory door lock switch
to the factory door lock control relay.
The green wire provides a ground pulse during disarming, or the pulsed ground unlock output. Connect
the green wire to the wire that provides a low current ground signal from the factory door unlock switch to
the factory door lock control relay.
3 Wire Positive Switched Door Locks
In this application, the red wire provides a positive pulse during disarming, or the pulsed + 12 volt unlock
output. Connect the red wire to the wire that provides a low current positive signal from the factory door
unlock switch to the factory door lock control relay.
The green wire provides a positive pulse during arming, or the pulsed + 12 volt lock output. Connect the
green wire to the wire that provides a low current positive signal from the factory door lock switch to the
factory door lock control relay.