F
PLUMBING
F - 15
MICROTECH™ FILTER
INSTALLATION/REPLACEMENT
1. Install a new filter by wetting the outlet ports with
water and then inserting into the round filter ports
on the faucet head and pushing the filter and head
together. Both outlet ports must be fully inserted into
the filter ports.
2. Install the filter and faucet head assembly on to the
spout by wetting the faucet head O-ring seal and
then carefully sliding the free end of the filter into
the spout. The head will need to be initially turned
approximately 1/2 turn counter clockwise from its
normal position to slip past the safety catch. Lock
the head into place by simultaneously pushing and
twisting the head clockwise. When properly installed
the head will feel secure, and will be correctly ori-
ented on the spout.
3. Reset the filter life indicator by pushing the filter
button 3 times. Wait 10 seconds. You should not be
running water while resetting the filter life indicator
because the filter button will remain depressed, with
the first push as it switches to filter mode. The filter
life indicator has been correctly reset if a short series
of rapidly flashing green light occurs, indicating that
the new filter-flushing period has begun.
4. Flush the filter for 5 minutes before initial use.
Your new Moen faucet is now ready for normal use.
To replace filter:
1. Turn off the faucet. Remove the faucet head by twist
-
ing it approximately 1/4 turn counter clockwise to
unlock it. Gently pull the faucet head away from the
spout and twist it approximately another 1/4 turn to
get the faucet head past the safety catch. The faucet
head and depleted filter (if one is installed) can now
be pulled completely out of the spout.
2. The filter is held to the faucet head by two outlet
ports, which connect into the head. Remove the old
filter by simply pulling it straight off. Discard the old
filter and install a new MicroTech 400 or 600 filter.
Note: The faucet will function correctly in unfiltered
stream mode with or without a filter installed. The
faucet will not function correctly in filter mode without
a filter. If a filter is not installed and the filter button
in depressed, unfiltered water will flow from both the
filtered water outlet and the stream outlet aerator, and
the filter button will not automatically stay depressed.
Use only Microtech 400 or 600 filter cartridges with
the PureTouch Classic Filtering Faucet system. The
Microtech filters are high performance carbon block fil-
ters developed specifically for the PureTouch system.
Filtering Appliance
Fa
ucet Head
O-Ring Seal
Spacer
Outlet
Ports
Filter