Mounting Requirements SENC 50
Mounting options can be adapted to machine mounting surfaces
using spacers, standoffs, and leveling screws.
• Measuring length and mechanical configuration of your
equipment determines your options.
• Length related mounting options shown.
• When a backup spar is used, mount the backup spar following
the same procedure as required for mounting without a backup
spar, using the same tolerances.
• 7” and smaller: End mounting holes with encoder mounted to
a continuous flat surface, or with center surface on same plane
as end mounting surfaces.
• 8” and larger: End mounting holes with center support.
Acu-Rite Companies Inc. 6
End mounting holes
Center support
assembly