Check function of the linear encoder.
These steps will confirm proper operation of your installation.
Counting tests check channel A and B output function and
Reference Mark tests check Reference Mark operation.
Configure the readout for proper counting resolution.
Move axis and compare the display to the movement.
Repeat test for mechanical integrity and repeatability.
Configure the readout for sensing reference mark.
Move the reading head approximately 20mm.
Locate an indicator on scale end and zero out axis and
indicator.
• Move axis out and back over full travel and return to dial
zero.
Electronics should read zero ± 1 count.
Acu-Rite Companies Inc. 10
Checking the Installation SENC 50
Zero the display and indicator.
Move axis to the end of it’s travel, then return to dial zero.
Readout should read zero ± 1 count.
Repeatability Test
Place indicator at end of
moving component (scale case
shown, or reading head).
Route the cables with slack loops to allow for axis motion.
Secure excess cable by fastening with clips or ties.
Attach the linear encoder connectors to the readout.
Readout
Counting Test
Connecting
Secure excess
cable
Provide slack
loops
Readout