ST80 Maxiview Operation and Setup
35
The following table lists the alarm status once a silence/turn off
key- sequence is performed.
Alarm Silenced Turned Off
Shallow depth Yes No
Deep depth No Yes
Anchor Yes No
True wind high speed No Yes
True wind low speed No Yes
True wind high angle No Yes
True wind low angle No Yes
Apparent wind high speed No Yes
Apparent wind low speed No Yes
Apparent wind high angle No Yes
Apparent wind low angle No Yes
Manual off-course Yes No
Full ST80 watch Yes No
If an alarm is currently active and an alarm of greater importance is
received, the current alarm is replaced with the new alarm.
Replaced alarms are not stored by the Maxiview. However, the
alarm remains on SeaTalk and, if the condition still exists once the
current alarm has cleared, will be reinstated.
Silenced alarms will repeat after 30 seconds if the condition persists.
Audible Alarms
There are basically two types of audible alarm: high priority and low
priority.
High priority alarms beep continuously while low priority alarms
consist of three beeps followed by a 5 second break.
High priority alarms will always override low priority alarms.
Once a high priority alarm has cleared, the previous alarm, if it is
still current, will be reactivated.