29
THREE PHASE WIRING DIAGRAM
A1
A1
Y/BK
ON/OFF
SWITCH
ON
OFF
40-32357F
A
XFMR
(TB2)
J2 PLUG
ON PCB
POWER IN
SEE NOTE 1
AB
CD
TO MOTOR
SEE NOTE 5
MOTOR
OVERLOAD
AUXILIARY RELAY
EXTERNAL OVERLOAD
LINE
BLACK (SL595 ORANGE)
SEE NOTE 3
LOAD
24VAC/60VA
BLUE
YELLOW
FUSE 3.2A
FREE EXIT LOOP
RADIO
TERMINAL
BLOCK
FACTORY
INSTALLED RADIO
(100db)
SAFETY
ALARM
-
+
1
2
3
456789
10
12
13
14
15
16
17
18
19
20
11
(TB1)
PURPLE
PUR/WHT
RESET
STOP
GREEN
YEL/BLK
BROWN
ORANGE
GREEN
GRAY
BLACK
BLACK
BLUE
WHITE
RED
OR/BLK
BLUE
OR
TB1-7
GRN
TB1-4
Y/BK
TB1-3
OPEN
CLOSE
STOP
TB1-5
J1-3
Y/BK
RESET
RADIO
SHADOW
VDC COM
CLOSE
STOP
SOFT OPEN
HARD OPEN
INTERRUPT
OPEN CLOSE
EDGE/PHOTO
EYE
MASTER
SECOND
MAGLOCK
EXIT LOOP
FIELD CONNECTIONS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
J1
J4
1 2
J2
(GL CONTROL BOARD)
Y/BK
TO J2-1
CONTACTOR
TB2-CD
PURPLE
Y (SL595 WHT)
GY (SL595 GN)
PU (SL595 RD)
A1
13
5
3
1
A2
14
6
4
2
B
A1
13
5
3
1
A2
14
6
4
2
WHITE
ORANGE
TO J2-2
WHITE
BLACK
BK
BK
BK
BLUE
YELLOW
BLUE
YELLOW
RPM
BOARD
ORANGE
PURPLE
GREEN
GROUND
CONTACTOR A
CONTACTOR B
ORANGE
PURPLE
BLACK
RED
WHITE
11
10
9
8
7
6
5
2
1
4
3
TB1-15
TB1-3
TB1-6
ALARM
4
R1
R2
R3
R4
BLUE
BLACK
Y/BK
BROWN
GREEN
OR
PU
1
2
L/S “A”
NC
C
L/S “B”
NC
C
YEL/BLK
Y/BK
3
GY
1
3
2
BL-BK
BL-BK
230V
BRAKE
SOLENOID
230V CONNECTION
LOOP WIRING
R4
TB1-5
TB2-AB
TB2-CD
FREE EXIT
LOOP
HARNESS
(10 PIN)
TB1-8
TB1-3
TB2-AB
TB2-CD
INTERRUPT
LOOP
HARNESS
(10 PIN)
4
6
7
8
9
10
BK
BK
PU
7
8
9
4
5
6
460V CONNECTION
230V
BRAKE
SOLENOID
1
3
2
BL-BK
BL-BK
BK
BK
PU
7
8
9
4
5
6
Y
Y
575V CONNECTION
575V
BRAKE
SOLENOID
BL-BK
BL-BK
1
3
2
GY
BK
BK
PU
Y
GY
R1
R2
YELLOW
BK
BK
BK
L1
L2
L3
BK
SEE NOTE 5
EXTERNAL
OVERLOAD
NOTES:
1. VOLTAGE: 208/230/460/575 VOLT 3 PHASE.
2. HORSEPOWER: 1/2, 1 & 2 HP.
3. TRANSFORMER PRIMARY VOLTAGE IS THE SAME AS THE OPERATOR LINE VOLTAGE. SECONDARY 24V/60VA.
FOR REFERENCE PRIMARY WIRE COLORS: 120V BLACK, 208V RED, 230V ORANGE, 460V PURPLE, 575V GREY
4. TERMINAL BLOCK IN LIMIT SWITCH ENCLOSURE (SL595 ONLY).
5. THREE PHASE UNITS ARE EQUIPPED WITH AN INTERNAL PILOT DUTY THERMAL OVERLOAD
DEVICE OR AN EXTERNAL LINE MONITORING SYSTEM.
24 VAC
RADIO
SIGNAL
TB2-20
TB2-19
TB2-18
TB2-17
To protect against fire and electrocution:
• DISCONNECT power BEFORE installing or servicing operator.
WARNING
YELLOW
24 VAC ACCESSORY
POWER
INTERRUPT
LOOP
Y/BK
RD
BK
4
6
7
8
9
10
G
YELLOW
Y/BK