20
EEC3 System Manual
4.3 Deleting Alarm Codes and Resetting Alarm Count to Zero
Once the alarm codes have been recorded you can determined the cause of the alarm. Use the Alarm Codes Description
Chart (page xx) to determine the cause of the problem and repair. Before exiting Alarm / Troubleshoot Mode you can delete
the alarm codes stored in memory and reset the alarm count to zero. To do this, follow the following step:
4.4 Exit Alarm / Troubleshooting Mode
When alarm codes have been reviewed and repairs made to system, return to normal operation by following the step below:
Press SYNC
to view
Alarm
Codes
LEDs alternating every 4 seconds
Pressing the SYNC button will allow you
to cycle through the 16 most recent alarm
codes. Record the sequence of blinking
LEDs on page 5. Determine the alarm
code by using the chart on page 6 and fill
in the appropriate space on the chart.
2
Record
Alarm
Count
All LEDs slow blinking
Record the sequence of
blinking LEDs in the
space provided on page
4. Determine the number
of counts from the chart.
1
All LEDs fast blinking
LEDs alternate between slow & fast blinking every 4 seconds
Press SYNC
& WARM
buttons
All LEDs flashing
NEUTRAL
Out of
NEUTRAL
Out of
NEUTRAL
To Exit Handle Troubleshoot Mode:
1—Power system OFF
2—Move handles back to NEUTRAL.
3—Restart system.
Press SYNC & WARM buttons any-
time after entering Handle
Troubleshoot Mode to delete alarm
codes & reset alarm count to zero.
All LEDs will flash to indicate alarm
codes have been deleted.
1
Power OFF &
Move
handles
into
NEUTRAL
1
4.25"
(108 mm)
6.80"
(172mm)
1.5" (38mm)
below panel
5.88" (150mm)