4-7
Figure 4-8 OTHER menu
3. Press the [3] key several times to select STOP from the TX/ANT field.
4. Set the range to 0.125 nm.
5. Connect a multimeter, set to the 10 VDC range, between J829 #1 (+) and #2 (-) in the
scanner unit.
6. Adjust the position of the sliding contact R812 to show a value between 7.0 V and 7.6
V on the multimeter.
7. Remove the TX-HV fuse (F801, 0.5A) from the power supply unit.
8. Transmit on maximum range.
9. Adjust the position of the sliding contact R811 to show a value between 4.7 V and 5.3
V on the multimeter.
10.Insert TX-HV fuse F801.
11.Set TX/ANT to ROTATE on the OTHER menu.
Figure 4-9 Scanner unit, power supply unit PSU-002
12. Press the [ENTER/SELECT] key to finish.