Specified microprocessor is out of
acceptable temperature range and is
operating at a reduced speed, or
frequency.
Ensure that the system cooling fans are properly installed. If the problem persists,
replace the faulty fan(s) (see "System Fans"). If the problem persists, ensure that the
microprocessor heat sinks are properly installed. If the problem persists, replace the
faulty microprocessor (see "Microprocessors").
No power available from the specified
power supply; specified power supply is
improperly installed or faulty.
Ensure that the power supplies are properly installed. If the problem persists, replace
the faulty power supply(s) (see "Power Supplies").
Insufficient power is being supplied to the
system; power supplies are improperly
installed, faulty, or missing.
Correctable errors threshold was met in a
memory bank: errors were remapped to
the spare bank.
Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "Memory Modules").
Memory modules installed in the specified
bank are not the same type and size;
faulty memory module(s).
Ensure that all banks contain memory modules of the same type and size and that
they are properly installed. If the problem persists, replace the faulty memory module
(s) (see "Memory Modules").
Parityfailureinthefirst64KBofmain
memory.
Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "Memory Modules").
Main-memory refresh verification failure.
Ensure that all banks contain memory modules of the same type and size and that
they are properly installed. If the problem persists, replace the faulty memory module
(s) (see "Memory Modules").
Multiple single-bit errors on a single
memory module.
Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "Memory Modules").
Faulty or improperly installed hard drive or
RAID controller.
Ensure that the hard drives are properly installed. If the problem persists, replace the
faulty hard drive(s) (see "Hard Drives"). If the problem persists, replace the RAID
controller (see "Integrated RAID Controller" and "RAID Controller Card").
CMOS write/read failure; faulty system
board.
Replace the system board (see "System Board").
Microprocessor speed control sequence
failure.
Ensure that the microprocessors are properly installed. If the problem persists,
replace the faulty microprocessor(s) (see "Microprocessors").
DMA initialization failure; DMA page
register write/read failure.
Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "Memory Modules").
Replace the system board (see "System Board").
Faulty keyboard controller; faulty system
board.
Replace the system board (see "System Board").
Main-memory refresh verification failure.
Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "Memory Modules").
Master or slave PIC register test failure.
Replace the system board (see "System Board").
Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "Memory Modules").
Super I/O chip failure; faulty system
board.
Replace the system board (see "System Board").
Programmable interval timer test failure;
faulty system board.
Replace the system board (see "System Board").
Faulty or improperly installed expansion
card.
Ensure that the expansion cards are properly installed. If the problem persists,
replace the faulty expansion card(s) (see "Expansion Cards").
Specified microprocessor is faulty,
unsupported, improperly installed, or
missing.
Ensure that the microprocessors are properly installed. If the problem persists,
replace the faulty microprocessor(s) (see "Microprocessors").
BIOS disabled logging errors.
Check the SEL for details on the errors.
Faulty or improperly installed expansion
card; faulty system board.
Ensure that the expansion cards are properly installed. If the problem persists,
replace the faulty expansion card(s) (see "Expansion Cards"). If the problem persists,
replace the system board (see "System Board").
Faulty or improperly installed
microprocessor or system board.
Ensure that the microprocessors are properly installed. If the problem persists,
replace the faulty microprocessor(s) (see "Microprocessors"). If the problem persists,
replace the system board (see "System Board").
Replace the system board (see "System Board").
Machine check error; faulty or improperly
installed microprocessor; faulty system
board.
Ensure that the microprocessors are properly installed. If the problem persists,
replace the faulty microprocessor(s) (see "Microprocessors"). If the problem persists,
replace the system board (see "System Board").
Replace the system board (see "System Board").
Faulty or improperly installed memory
module; faulty system board.
Ensure that the memory modules are properly installed. If the problem persists,
replace the faulty memory module(s) (see "Memory Modules"). If the problem
persists, replace the system board (see "System Board").
Replace the system board (see "System Board").
Operating system watchdog timer timed
out.
Restart your system. If the problem persists, see your operating system
documentation.