A SERVICE OF

logo

5
ONE YEAR LIMITED WARRANTY
For a period of one (1) year from date of purchase, Atd Tools Inc. will repair or replace, at its option, without charge,
any of its products which fails due to a defect in material or workmanship, or which fails to conform to any implied
warranty not excluded hereby.
Performance of any obligation under this warranty may be obtained by returning the warranted product, freight
prepaid, to Atd Tools Inc. Warranty Service Department, 160 Enterprise Drive, Wentzville, MO 63385.
Except where such limitations and exclusions are specifically prohibited by applicable law. (1) the CONSUMER'S
SOLE AND EXCLUSIVE REMEDY SHALL BE THE REPAIR OR REPLACEMENT OF DEFECTIVE PRODUCTS AS
DESCRIBED ABOVE, and (2) Atd Tools Inc. SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDEN-
TAL DAMAGE OR LOSS WHATSOEVER, and (3) THE DURATION OF ANY AND ALL EXPRESSED AND IMPLIED
WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, IS LIMITED TO A PERIOD OF ONE (1) YEAR FROM DATE OF PURCHASE.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to
you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have
other rights which vary from state to state.
TROUBLESHOOTING
Symptom
Possible Causes Corrective Action
Hydraulic unit will not lift load
Hydraulic unit bleeds off after
lift
Will not lift to full extension
• Release valve not tightly closed
• Overload condition
• Fluid level low
• Fluid level low
• Air trapped in system
• Release valve not tightly closed
• Overload condition
• Hydraulic unit malfunction
• Ensure release valve tightly closed
• Remedy overload condition
• Ensure release valve tightly closed
• Remedy overload condition
• Contact Atd Tools Tech. Service
• Ensure proper fluid level
• Ensure proper fluid level
• With ram fully retracted, remove oil
filler plug to let pressurized air escape,
then reinstall oil filler plug
Poor performance
Hydraulic unit will not lower
after unloading
• Reservoir overfilled
• Linkages binding
• Drain fluid to proper level
• Clean and lubricate moving parts
Atd7227-M0