![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/c/32/c32cc7ba-622a-46ff-9a3a-b3e802abb11f/c32cc7ba-622a-46ff-9a3a-b3e802abb11f-bgb.png)
9
ATTIX 791-2M/B1
7.2.2 Replacing the waste
bag
1. Remove the upper section of
cleaner from the dirt tank.
2. Open the retaining clamps
(1) and remove the interme-
diate ring (2) from the tank.
3. Close the waste bag using
the cable binder (3).
4. Dispose of the dirt in accord-
ance with legal regulations.
5. Insert a new filter bag into the
cleaned tank as described in
the instructions enclosed.
Only after picking up nonhazardous
dust or dust with MAC values
>1 mg/m³.
1
3
1
2
3
1
1
2
7.2.3 Replacing the filter bag
During the following work, en-
sure that dust is not unnecessarily
spread around. Wear a P2 breath-
ing mask.
1. Open the retaining clamps and
remove the upper section of the
cleaner from the dirt tank.
2. Carefully remove the filter bag
connection from the inlet fitting.
3. Close the filter bag connection
with the slide.
4. Dispose of the filter bag in ac-
cordance with legal regulations.
5. Place a new filter bag into the
cleaned tank as described in the
instructions (printed on the filter
bag)
IMPORTANT: Press the filter
bag connection on the inlet fit-
ting as far as possible.
7.2.4 Emptying the dirt tank
1. Remove the upper section of
cleaner from the dirt tank.
2. Open the retaining clamps
(1) and remove the interme-
diate ring (2) from the tank.
3. Pull the lever in the handle
(3) upwards and tilt the tank.
4. Tip out the collected dirt.
5. Dispose of the dirt in accord-
ance with legal regulations.
or:
3. Open the tank locks (4).
4. Use the handles (5) to lift the
tank out of the frame.
Only after picking up
harmless dust with-
out a filter bag.
To empty the dirt
tank after picking
up liquids: remove
the intermediate ring as a proper
seal is only ensured during suction.
After emptying the tank: clean the
rim of the tank and the seals in the
intermediate ring and the upper
section of cleaner before refitting
them.
If the seal or groove is dirty or dam-
aged, the suction performance will
be reduced.
Before reinserting the suction hose:
clean the inlet fitting and hose col-
lar.