Yamaha XVS250 Motorcycle User Manual


 
PERIODIC MAINTENANCE AND MINOR REPAIR
6-9
6
5. Remove and replace the oil filter
element and O-ring.
6. Install the oil filter element cover by
installing the bolts, then tightening
them to the specified torque.
N
O
TE:
Make sure that the O-ring is properly
seated.
7. Install the engine oil drain bolt, and
then tighten it to the specified
torque.
8. Add the specified amount of the
recommended engine oil, and then
install and tighten the oil filler cap.
CAUTION:
ECA11620
In order to prevent clutch slip-
page (since the engine oil also
lubricates the clutch), do not
mix any chemical additives. Do
not use oils with a diesel speci-
fication of CD or oils of a high-
er quality than specified. In
addition, do not use oils labeled
ENERGY CONSERVING II or
higher.
Make sure that no foreign mate-
rial enters the crankcase.
9. Start the engine, and then let it idle
for several minutes while checking
it for oil leakage. If oil is leaking, im-
mediately turn the engine off and
check for the cause.
10. Turn the engine off, and then
check the oil level and correct it if
necessary.
1. Bolt
1. Oil filter element
2. O-ring
Tightening torque:
Oil filter element cover bolt:
10 Nm (1.0 m·kgf, 7.2 ft·lbf)
Tightening torque:
Engine oil drain bolt:
34 Nm (3.4 m·kgf, 25 ft·lbf)
Recommended engine oil:
See page 8-1.
Oil quantity:
With oil filter element replacement:
1.60 L (1.69 US qt) (1.41 Imp.qt)
Without oil filter element replace-
ment:
1.40 L (1.48 US qt) (1.23 Imp.qt)
5KRE2.book Page 9 Monday, June 23, 2003 3:32 PM