Ultimate Technology ULG 3.8 A1 Automobile Battery Charger User Manual


 
10 GB/IE
Operation
©
Reset / deleting settings
After connection to the power supply, the appliance
automatically returns to its basic setting and remains
in STANDBY mode
©
Switching between modes 1,
2, 3 and 4
˽ Press the MODE selection button
9
the appro-
priate number of times.
The device switches between charging modes in
the following order: Standby
, MODE 1
„6 V“, MODE 2
, MODE 3 , MODE 4
and then repeats the cycle
NOTE: If a 12 V battery is connected, MODE 1 “
6 V”
cannot be selected. If a 6 V battery is connected,
MODES 2, 3 and 4 “12 V” cannot be selected.
NOTE: If you press the selector button
9
, charging
mode automatically switches over to the next mode
and begins operation in that mode.
NOTE: However, if a battery is not disconnected
from the charging station after a full charge, the
appliance remains in trickle-charge mode, even if
the user switches over to another mode. This pro-
tects the battery from being damaged.
©
Mode 1 „6 V“ (7.3 V / 0.8 A)
This mode is suitable for charging 6 V lead-acid
batteries with a capacity less than 14 Ah.
˽ Press the selection button MODE
9
, to select
mode 1. After doing so, the corresponding LED
display „6 V“
2
lights up. If you do not activate
an-other process afterwards, the electronic sys-
tem will automatically start the charging process
together with the LED display
8
at (with a
current of) 0.8 A ± 10 %. If the procedure runs
without any problems, the LED display
8
remains on during the entire charging proc
ess,
un-
til the battery is fully charged at 7.3 V / ±
0.25 V.
When the battery is fully charged, LED display
7
lights up and LED display
8
goes
out. The device now switches automatically into
maintenance charging mode.
©
Mode 2 „12 V“ (14.4 V / 0.8 A)
This mode is suitable for charging 12 V lead-acid
batteries with a capacity less than 14 Ah.
˽ Press the selection button MODE
9
, to activate
mode 2. After completion of this process, the
appropriate LED indicator
3
lights up.
Then if you do not take any further action, the
electronic control and the LED indicator
8
automatically switches on and starts the charg-
ing process. If the procedure runs without any
problems, the LED display
8
remains on
during the entire charging process, until the
battery is fully charged. When the battery is
fully charged, LED display
7
lights up and
LED display
8
goes out. The device now
switches automatically into maintenance charg-
ing mode.
©
Mode 3 „12 V“ (14.4 V / 3.8 A)
This mode is mainly suitable for charging 12 V
lead-acid batteries with a capacity greater than
14 Ah under normal conditions.
˽ Press the selection button MODE
9
, to activate
mode 3. Then if you do not take any further ac-
tion, the electronic control and the LED indicator
4
switches on and starts the charging pro-
cess. If the process runs without any problems,
the LED indicator
8
remains on during the
whole charging process until the battery is
charged. When the battery is fully charged, the
LED indicator
7
and the die LED indicator
8
go out. The device now switches auto-
matically into maintenance charging mode.