6. Ignore Open Door Report. Bypasses the open zone warning chirps for vehicles equipped with a
residual dome light circuit that remains ON for a period of time after closing the door.
7. Auto Rearming Mode. When selected, the system will automatically re-arm and lock 30 seconds after
it has been disarmed regardless if a door is open or closed.
8. Door Unlock Pulse. Selects between one pulse or two pulse operation for the door unlock output.
Vehicles that require two pulses on the proper wire to unlock the doors can be interfaced directly without
the use of relays or any additional circuitry by programming the system for double unlock pulse.
9. Arming Chirps. Selects between normal and silent operation.
10. Disarm with Auxiliary 1. When selected, activating the Auxiliary 1 output (usually used to open the
trunk) will disarm the alarm.
11. Door Lock Pulse Length. Selects between a 1, 3 or 0.1 second output for door locking and unlocking.
Program to 3 seconds for vehicles equipped with vacuum door locking systems.
12. Anti-Carjack Type. Selects one of three modes for Anti-Carjacking: Active, Passive, or Full-Time.
Manual.
When selected, pressing Button 4 will automatically engage the Anti-Carjacking feature.
Passive.
When selected, the Anti-Carjacking feature will activate whenever a door is opened while the
ignition is on.
Ful
l-Time. When selected, the Anti-Carjacking feature will automatically activate each time the ignition is
turned on.
13. Anti-Carjack Mode. Enables Anti-Carjacking protection.
14. Horn Honk Output. Selects the output, when activated, to be pulsing or constant.
15. Aux 2 Auto Activate with Arm. When selected, the Auxiliary 2 output will activate when the system
is armed. This feature can be used to roll-up windows, close sunroofs, activate accessories, etc.
16. Auxiliary 1 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 1.
Momentary operation provides an output for as long as the transmitter button is pressed.
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is
pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and remains
on until the transmitter button is pressed again.
17. Auxiliary 2 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 2.
Momentary operation provides an output for as long as the transmitter button is pressed.
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is
pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and remains
on until the transmitter button is pressed again.
18. Ignition Armed Mode. When enabled, the security system may also be manually armed and disarmed
using the transmitter, while the ignition is on.
19. Extended Parking Lights. When selected, the parking lights will remain ON for 30 seconds after
disarming the system.
20. Warn-Away Pager Report. When Enabled, Warn-Away report will be sent to the pager. If Disabled
no Warn-Away report will be sent to the pager.