Scytek electronic ASTRA 777 Automobile Alarm User Manual


 
Page 16 - Astra 777
Plug-in Connectors
3-Pin White Door Lock Connector: Plug-in connector port for door lock harness or optional door lock
relay module.
· BLUE WIRE - negative unlock output (-) 500mA.
· GREEN WIRE - negative lock output (-) 500mA.
2-Pin Red Connector: Plug-in connector port for LED. Mount the LED in an area where it may be easily
seen from either side of the vehicle.
2-Pin Blue Connector: Plug-in connector port for valet switch. Mount the valet switch in an area that is
easily accessible from the driver’s position.
4-Pin White Connector : Plug-in connector port for dual stage shock sensor.
Jumper Selection
Carefully separate the top and bottom halves of the main unit case. Once the cover is removed, the parking
light polarity jumper will be visible next to the parking light relay. Set the jumper for the correct polarity
output as described below, then reassemble the main unit case.
Parking Light Output. Selects the polarity (+/-) for the output of the on-board Parking Light relay.
Left Pin + Center Pin = positive
Right Pin + Center Pin = negative
Jumper
Settings
default setting shown