5. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when
the ignition is turned off. The Ignition Door Locking feature may be programmed to unlock all doors
or the driver’s door only. If driver’s door only is selected, the optional Passenger Unlock wire must
be connected. (
See Two Stage Door Lock Diagrams
)
6. Door Unlock Pulse. Selects between one pulse or two pulse operation for the door unlock output.
Many new import vehicles’ factory door locking systems require two pulses on the proper wire to
unlock the doors. These systems can be interfaced directly without the use of relays or any
additional circuitry by programming the system for double unlock pulse.
7. Door Lock Pulse Length. Selects between a 1, 3 or 0.1 seconds output for door locking and
unlocking. Program to 3 seconds for vehicles equipped with vacuum door locking systems.
8. Passive Door Locking. Selects whether or not the system will automatically lock the doors during
Passive Arming.
9. Remote Start Confirmation Chirps. When enabled, system chirps before starter is activated.
When disabled, no chirps will sound upon start.
10. Ignore Open Door Report. Bypasses the open zone warning chirps for vehicles equipped with a
residual dome light circuit that remains on for a period of time after closing the door.
11. Auxiliary 1 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 1.
Momentary operation provides an output for as long as the transmitter button is pressed.(1-way
remote only)
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is
pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and
remains on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be
programmed to output for 1 second up to 255 seconds.
12. Auxiliary 2 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 2.
Momentary operation provides an output for as long as the transmitter button is pressed.(1-way
remote only)
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is
pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and
remains on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be
programmed to output for 1 second up to 255 seconds.
13. Auxiliary 3 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 3.
Momentary operation provides an output for as long as the transmitter button is pressed.(1-way
remote only)
Timed operation provides an output that turns on for 10 seconds each time the transmitter button is
pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched operation provides an output that turns on when the transmitter button is pressed and
remains on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be
programmed to output for 1 second up to 255 seconds.