100
MAINTENANCE
Front Gearcase (Demand Drive) Fluid
Fluid Level
1. Position the vehicle on a level surface.
2. Remove the fill plug. Check the fluid level.
3. Add the recommended demand drive fluid as needed to bring the
level to the bottom of the fill hole threads.
4. Reinstall the fill plug. Torque to 8-10 ft. lbs. (11-14 Nm).
Fluid Change
1. Position the vehicle on a level surface.
2. Remove the fill plug.
3. Place a drain pan under the demand drive unit.
4. Remove the drain plug. Allow the fluid to drain completely.
5. Clean and reinstall the drain plug. Torque to 11 ft. lbs. (15 Nm).
6. Add the recommended fluid. See page 99 for capacity. Maintain the
fluid level at the bottom of the fill hole threads.
7. Reinstall the fill plug. Torque to 8-10 ft. lbs. (11-14 Nm).
8. Check for leaks.
9. Dispose of used fluid properly.
Active Descent Control (ADC) Fluid
If your vehicle is equipped with Active Descent Control, there are two
fluid levels that must be maintained (demand drive fluid and ADC
fluid). See page 99 for demand drive fluid maintenance.
Check and change the ADC fluid level at the intervals outlined in the
Periodic Maintenance Chart beginning on page 85. Maintain the fluid
level between the minimum and maximum marks on the reservoir. We
recommend the use of Polaris ADC Fluid. See page 143 for the part
numbers of Polaris products.
NOTE: Do not use brake fluid. Brake fluid will damage rubber components in
the hydraulic system.