Omega FPDM1000 Automobile Parts User Manual


 
13
SPECIFICATIONS
Mechanical Meter Models
Flow Ranges (LPM or GPM)
Above 5 centipoise 15 to 350 / 3.96 to 92.46
Below 5 centipoise 30 to 300 / 7.93 to 79.25
Accuracy of Reading ± 1%
Maximum Viscosity
*
1000 Centipoise
Maximum Operating Pressure
**
1800 kPa / 260 PSI / 18 Bar
Operating Temperature Range -10°C to +80°C (+14°F to +176°F) - Aluminum
-10°C to +120°C (+14°F to +248°F) - Stainless Steel
*
Unless High Viscosity Rotors are fitted.
**
Meter conforms to PED 97/23/EC CAT 1.
Item Rec. Part or Set
No. Qty. Parts (Order from this column only) Part Description
12 6 u MS312S Coverplate Screws - Litre Model
12 6 u MS313S Coverplate Screws (S/Steel) - Litre Model
12 6 u MS419S Coverplate Screws - US Gallon Model
12 6 u MS420S Coverplate Screws (S/Steel) - US Gallon Model
13 1 u MS83S Bevel Gear Set
14 1 MS140 Bottom Register Coverplate
15 4 u MS111S Mounting Screws
16 1 u MS141S Register Assembly with Coverplate - Litres
16 1 u MS141US Register Assembly with Coverplate - US Gallons
17 4 u MS129S Register Body Screws
20 1 u MS423S Spacer Ring (Aluminum) - US Gallons Model Only
20 1 u MS423-1S Spacer Ring (S/Steel) - US Gallon Model Only
Note: Complete Register Assembly Part Numbers; “Litre” Register - MS84, “US Gallons” Register - MS84U.
DIMENSIONS