Setting the low fuel alarm
Use the key to select the alarm function. The LCD
will indicate
ALr
for two seconds and will then display
the present alarm value. If no alarm value has been
entered the LCD will indicate
0FF
.
TOTALFLOW
^
V
ALr
0 12 0FF
Press and hold both keys for three seconds and the
displayed value will begin to flash.
Press and hold for 3 seconds
8 12
Use the and keys to select the desired alarm
value. Press and hold both keys for one second to
save this new value to memory and to exit this function.
The display will indicate
ALr
and then the new value.
ALr
8 14
#
The arrow pointing at the alarm bell will be activated.
Alarm activation
If the fuel remaining value drops below the fuel alarm
value, the alarm will sound and the alarm arrow will
flash.
12
#
Press any key to mute the alarm. The alarm arrow
will continue to flash as long as the alarm condition
remains.
Resetting the TRIP LOG or
the TOTAL LOG
To reset a log, press the key until the display
indicates the name of the log to be reset.
Press and hold both keys for three seconds. Display
will show
trP
or
tOt
for 2 seconds before resetting
to zero.
Press and hold for 3 seconds
0 00
trP tOt
The trip log value may be reset without changing
the total log value.
If the total log is reset to zero, then the trip log
will automatically reset to zero.
Note :
If the total log exceeds 999 then both it