QP3TY — INITIAL START-UP (ENGINE)
Stopping The Engine
Normal Shutdown
1. Move the engine speed lever to the low speed and run the
engine for about three minutes with no load.
2. After the engine cools, move the engine speed lever to the
STOP position (Figure 11).
3. Close the fuel cock (Figure 12).
4. Slowly pull the starter grip (Figure 9) until strong resistance
is felt and leave it in this position. This prevents rust from
forming while the engine is not in use.
When stopping the engine, reduce the load slowly. Do
not stop engine suddenly since it may cause the
temperature to rise abnormally.
CAUTICAUTI
CAUTICAUTI
CAUTION
Emergency Shutdown
1. To stop engine immediately, quickly place the engine speed
lever to the STOP position.
Figure 11. Engine Speed Lever (STOP Position)
Figure 12. Close Fuel Cock
STOP
ENGINE SPEED
LEVER