Maretron TLM150 Automobile Accessories User Manual


 
TLM150 User’s Manual
Page 14 Revision 1.2
6 Technical Specifications
Specifications
Parameter Value Comment
Accuracy ±2%
Resolution ±1%
Number of Tank Types 1 Fuel (Gasoline only)
Number of Tanks per Tank Type 16 16 Tanks per Tank Type Numbered 0-15
Maximum Tank Depth 24” (0.61m)
Minimum Depth Reading 2” (5.08cm) Sensor Deadband
Support for Irregularly Shaped
Tanks
Yes Can be Calibrated for any Shape Tank
Programmable Tank Capacity Yes Allows Displays to Calculate Amount Remaining
Maximum Tank Angle Without focus tube
15° With focus tube
Certifications
Parameter Comment
NMEA 2000 Level B+
Maritime Navigation and Radiocommunication Equipment & Systems Tested to IEC 60945
FCC and CE Mark Electromagnetic Compatibility
NMEA 2000
®
Parameter Group Numbers (PGNs) - See Appendix A for Details
Description PGN # PGN Name Default Rate
Periodic Data PGNs 127505 Fluid Level 0.4 Times/Second
Response to Requested PGNs 126464 PGN List (Transmit and Receive) N/A
126996 Product Information N/A
126998 Configuration Information N/A
Protocol PGNs 059392 ISO Acknowledge N/A
059904 ISO Request N/A
060928 ISO Address Claim N/A
065240 ISO Address Command N/A
126208 NMEA N/A
Electrical
Parameter Value Comment
Operating Voltage 9 to 16 Volts DC Voltage
Power Consumption <100mA Average Current Drain
Load Equivalence Number (LEN) 2 NMEA 2000
®
Spec. (1LEN = 50mA)
Reverse Battery Protection Yes Indefinitely
Load Dump Protection Yes Energy Rated per SAE J1113