Dakota Digital UTV-1000 Automobile Accessories User Manual


 
page 4 MAN#650231:A
Pulls up all values  on speed and speed pulses in odometer
Press Right switch to finish cal and save value
ADJUST Adjust speed cal while driving
ADJUST Each press of left switch toggles direction of adjustment, right switch to save and exit
SRV MI (SRV KM) Sets value of service odometer set when service odometer is reset
OFF ( OFF) Turns off the count down service odometer (default)
500 ( 800) Sets service to 500 mi or 800 km when resetting service odometer.
…. Service point can be set in 500 mi (800km) increments.
7500 (12000) Sets service to 7500 mi or 12000 km when resetting service odometer.
MAIN Returns to info menu
TACH Tachometer gauge menu
ENGINE Sets number of cylinders from 1-15 (default 12 for use on alternator output)
WARN Sets RPM warning point (default 5500 RPM)
W 2250 Minimum warning point of 2250 RPM
…. Warning point can be set in 250 RPM increments
W 9750 Maximum warning point of 9750 RPM
SRV HR Sets service hour value used when resetting count down service hour meter
OFF Service hour meter disabled (default)
10 Minimum service hour set point
Service hour reset point can be set in 10 hr increments
310 Maximum service hour set point
MAIN Returns to info menu
GAUGES Gauge option menu
VLT HI Set high voltage warning point (default 15.4V)
VLT LO Set low voltage warning point (default 11.1 V)
FL SND Set fuel sender used
NONE No fuel sender used, fuel area will be blanked out (default)
STOCK Uses stock fuel sender for Rhino
DAKDIG Uses Dakota Digital sender to be installed in tank
CUSTOM Uses custom sender, user must calibrate for the sender curve
CAL Y (CAL N) Select CAL Y to calibrate sender
EMPTY Start with empty tank, or fuel sender in empty position
ADD 33 Fill fuel to 1/3 tank, press right switch to save point
ADD 66 Fill fuel to 2/3 tank, press right switch to save point
ADD 99 Fill fuel to full tank, press right switch to save point
DONE Custom fuel calibration is complete, press right switch to go back to menu
OIL LO Set low oil pressure warning point (default 9 PSI)
WTR HI Set high water temp warning point and set temperature unit (default 230F)
DEG F (DEG C) Select temp unit, press left switch to change, right switch to save
WTR HI Select high warning, left switch to change, right switch to save
MAIN Returns to info menu
OPTION Option menu
DIM LV Adjust dimming point on gauge
OFF Dimming function is off
LVL 1 Gauge will dim when light on gauge face is very low (default)
7 selectable dimming levels
LVL 7 Gauge will dim early when more light is on gauge face
DM OUT Enables/disables dim output for other gauges
ON Dim output will be high when gauge is dimming
OFF Dim output will be disabled (default)
WN OUT Selects which gauges provide a warn out signal on warn out wire (default all on)
WN OUT Gauges that provide signal out are lit up, left switch to change, right switch to save
NO WRN Warn output wire is disabled