This will write the settings to the control module. Wait until the module displays “Success” before disconnecting it from the antenna cable.
To reset the options, hold the “R” (reset) button and “W” (write) button for 2.5 seconds. To write the reset, hold the “W” button until the OP-500 chirps, which is approximately 2.5 seconds.
Option Programming Using a Remote
Using a remote is a timed process so read this section in its entirety before beginning. IMPORTANT: Diesel timer cannot be programmed with a remote – the OP500 must be used. If at
any time during the process you hear a long horn sound the system kicked you out of programming mode.
STEP 1: Select the option menu that contains the desired programming option. To select a menu, use the following button combinations:
*Buttons I, II, III, IV correspond to I = Lock, 2 = Unlock, 3 = Trunk, 4 = Start on 1 Way remotes
I+II for 2.5 sec. Menu 1
I+IV for 2.5 sec Menu 2
STEP 2: After entering the option menu that contains the desired option, tap button (IV) on two-way remotes for 0.5 seconds or buttons (Trunk + Start) on one-way remotes
for 2.5 seconds the number of times equal to the option number. Wait for a parking light flash and siren chirp between each button press. After selecting the desired option number
the system will confirm which option you have selected by the number of siren chirps and parking light flashes.
STEP 3: Once the system is finished confirming the option number, set the option to the desired setting by tapping buttons I or II. To set options with the one-way remote the
duration is different. Tap the Lock Button for Setting 1. Tap the Unlock Button for Setting 2.
Resetting to Factory Defaults: To reset the options in a particular menu group, enter the menu by following STEP 1, then tap button III for 0.5 sec, three times. Wait for the siren to chip
and parking lights to flash between each tap. After the third tap, the option menu will reset and the siren will chirp three times. This must be done for each option group that needs to
be reset.
Option Programming Using the 1-Way Antenna Button
Programming the main controller option using an antenna is a timed process so you should read the instructions entirely before beginning.
STEP 1: Turn vehicle’s ignition to the on position.
STEP 2: Selecting the Option Menu - Select the option menu that contains the option you would like to adjust. Be aware, the diesel timer and auxiliary times are not available when
programming options with an antenna. To select a menu, use the following button combinations:
STEP 3: Selecting the Specific Option - After entering the option menu that contains the option you wish to change, tap the antenna button the number of times equal to the option
number. you wish to change. A few seconds after you have stopped selecting an option, the system will confirm which option you have selected by the number of siren chirps and parking
light flashes.
STEP 4: Setting the Option - After the system is finished confirming the option number, set the option to your desired setting by tapping the antenna button 1 or 2 times.
Resetting to Factory Defaults: To reset the options in a menu, enter the menu as if you were going to program an option then hold the antenna button for three seconds. The option
menu will reset and the siren will chirp three times. The options in the other three menus will remain set.
Option Programming Tables
Hold antenna button until you hear/see 1 chirp/parking light flash. Menu 1
Hold antenna button until you hear/see 2 chirps/parking light flashes. Menu 2
Option Menu 1
Feature Factory Default - I Optional - II
1-01 Unlock Before, Start, Lock After Start OFF ON
1-02 Door lock / Unlock Pulse Duration 0.8 sec 2.5 sec
1-03 Crank Time w/ Alternator Sensing 0.8 sec 1.0 sec
1-04 Driver's Priority Unlock OFF ON
1-05 Double Pulse Unlock OFF ON
1-07 Turbo Mode OFF ON
1-08 Diesel Timer * Glow Plug Wire
3-99 sec.
(10 sec. default)
1-09 Short Pulse Lock / Unlock OFF 0.125 Sec
1-10 Starter Kill Relay Anti-Grind Only
Anti Grind + Starter
Kill
1-11 Manual Transmission Auto Lock
Lock After
Reservation
Does Not Lock After
Reservation
1-12 Delayed Door Trigger for Locking OFF 90 Sec Delay
1-13 Factory Style Alarm OFF ON
1-14 Rearm Wire Pulse
After Remote Start
Shutdown and First
Lock
After Remote Start
Shutdown Only
Option Menu 2
Feature Factory Default - I Optional - II
3