Clifford 50 Automobile Alarm User Manual


 
Multiple-event TotalRecall™
The system’s non-volatile memory records the identity of the last eight activated or
malfunctioning triggers and/or sensors, which allows your installer to instantly track down
malfunctions and save you substantial servicing costs. To identify the triggers and/or sensors
held in the system’s non-volatile memory, simply perform the following procedure:
1. With the ignition OFF, flick the PlainView valet switch to its latched side.
2. Press button I to “arm” the system, then again to “disarm.”
3. The LED will blink 1–6 times to indicate the most recently activated trigger or
sensor, pause, then blink 1–6 times to indicate the next most recently activated
trigger or sensor, and so on for the last 8 activations (beginning with the most recent).
4. Write down the number of blinks between pauses and refer to the chart below:
Number of LED blinks per cycle Trigger/sensor that was activated or malfunctioned
1 blink
Magnetic Resonance Sensor
2 blinks
Glass tampering sensor
3 blinks
Door trigger
4 blinks
Trunk trigger
5 blinks
Hood trigger
6 blinks
Proximity Sensor or other optional sensor
Headlight reminder
If you turn the ignition off and open the driver’s door to exit the car without having turned
off the headlights, you will be reminded to turn them off with a distinctive warning tone.
If your vehicle already has a similar warning feature, you may turn off your Concept
50’s Headlight Reminder. See the User-selectable features section on pages 19–21.
Remote QuickAccess™
For the greatest ease of use, the Remote QuickAccess features permit you a quick and
easy way of controlling, with just the remote, the most commonly used features. You
can control either of these features any time via your remote control. Here’s how:
QuickAccess Valet Mode: To enter valet mode remotely, transmit channel 10
(press the LevelShift button on the side of the remote control twice, then press
button 2). The parking lights will flash twice and the dashboard LED will stay on
to indicate the system is in valet mode. To exit valet mode remotely, transmit
channel 10 again and the system will exit of valet mode with one parking light
flash and the LED will turn off. (NOTE: If you enter valet mode via the remote
control, exit valet mode in the same manner. If you use the PlainView switch to
enter valet mode, use the switch to exit valet mode.)
QuickAccess Long-Term Chirp Silencing: To silence the chirps, transmit channel 9
(press the LevelShift button on the side of the remote control twice, then press
button 1). The parking lights will flash twice to indicate that long-term chirp
silencing is on. To restore the chirps, transmit channel 9 again and the system will
confirm restoration of the chirps with one flash of the parking lights.