Full trigger response 30 or 60 seconds: This determines how
long the full triggered sequence lasts. Some states have laws
regulating how long a security system can sound before it is
considered a nuisance. If your installer is programming the
security system with the Pro Security Programmer, the full
triggered response can be programmed for any duration
ranging from 1 to 180 seconds.
False alarm prevention Circuitry on or off: Please refer to the
false alarm prevention circuitry section of this manual for a
further explanation. If the false alarm prevention circuitry is
programmed off, the security system will respond to inputs
from any sensor indefinitely.
Progressive door trigger on or off: When the system is armed
and a door is opened, the system responds with ten chirps prior
to beginning the full triggered sequence. If an instant trigger is
desired, the progressive door trigger can be programmed off.
Override pulse count: The number of presses of the Override
switch required to disarm the security system, AED, or the
Anti-Carjacking system can be programmed from one to five
presses. The default setting is one press.
Siren tones and chirp volume: The output of the siren consists
nnoottee::
Because many states have laws regulating security sys-
tems, programming false alarm prevention circuitry off may
cause your system to violate state laws.
nnoottee::
This feature will only function if the Starter Kill relay has