Chicago Electric 96157 Automobile Battery Charger User Manual


 
Page 6SKU 96157
For technical questions, please call 1-800-444-3353.
Connect the black Negative Battery Clamp (28) to a non-moving metal part 4.
of the vehicle. DO NOT CONNECT TO THE NEGATIVE TERMINAL OF THE
BATTERY.
The Connection Indicator Light (17) will glow green if a correct connection has 5.
been made. If the Connection Indicator Light turns red, review, and change the
connections.
When the correct connection has been made, turn the Jump-start Power Switch 6.
(18) to the “ON” position.
Start vehicle. If vehicle does not start, wait an additional 3 minutes before trying 7.
again. Failure to wait 3 minutes may damage the Power Pack.
After vehicle is started, remove the black Negative Battery Clamp first, and then 8.
the red Positive Battery Clamp.
Air Compressor
Open Compartment Door (5) on the back of the unit and pull out the air hose. 1.
Check proper inflation level for the object that is being inflated.2.
Lift lever on air nozzle and connect the appropriate adapter (stored in the same 3.
area as the air hose and nozzle) for your intended use. Move lever down to lock
adapter in place.
Turn Air Compressor Switch (24) to “ON” position. (“0”=OFF, “1”=ON)4.
Watch the Compressor Gauge (15) on the front of the unit to avoid over-inflation. 5.
When the object reaches the proper inflation level, turn off Air Compressor and 6.
disconnect hose. Do not overinflate any object.
AC Inverter
Before connecting the Inverter, make sure the Inverter/Fan Switch (26) is in the 1.
“OFF” position. (Push on “0” portion of the switch)
Plug the appliance into an AC Socket (29) of the Power Pack.2.
Press the Inverter/Fan Switch to the “ON” position. If the inverter is working correctly, 3.
the light underneath the Inverter/Fan Switch will illuminate green.
Turn on the appliance, if the light remains on, the system is functioning normally. If 4.
the light turns off, immediately turn off the appliance and the inverter and see the
“Troubleshooting Guide” section of the manual.
Monitor voltage use, so that the Power Pack does not drain completely. 5.